A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of radial position on volume measurements using the conductance catheter. | LitMetric

A finite-difference computer model has been used to determine the potential distributions arising from a dipole current source aligned parallel to the axis of bounding cylinders. The radial position of this source had large and nonlinear influence on the potentials along the dipole axis. The accuracy of the computer simulation was established from comparison with an analytic solution of a simple geometry. Measurements using a conductance catheter in saline-filled cylinders also demonstrated the dependence of the conductance on the radial position. The dependence of the potential distribution on the radial position of the dipole places limits on the ultimate accuracy of the conductance catheter technique when used for the measurement of ventricular volume. Radial movement of the catheter within the ventricular cavity, resulting in changes in the potential distribution, could explain some artefacts that appear on volume recordings from the conductance catheter.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02442166DOI Listing

Publication Analysis

Top Keywords

radial position
16
conductance catheter
16
measurements conductance
8
potential distribution
8
radial
5
conductance
5
catheter
5
position volume
4
volume measurements
4
catheter finite-difference
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!