Nontoxic Formulations of Scintillation Nanocrystals for Use as X-ray Computed Tomography Contrast Agents.

Bioconjug Chem

School of Chemical Engineering, ‡Department of Veterinary Clinical Sciences, §Department of Comparative Pathobiology, and ∥Purdue University Center for Cancer Research, Purdue University, West Lafayette, Indiana 47907, United States.

Published: January 2017

X-ray computed tomography (CT) is currently one of the most powerful, noninvasive, clinical in vivo imaging techniques, which has resulted from advances in both X-ray device and contrast enhancement technologies. The present study demonstrates, for the first time, that metal tungstates (such as CaWO) are promising contrast agents for X-ray, radiation, and CT imaging, because of the high X-ray mass attenuation of tungsten (W). We have developed a method of formulation, in which CaWO (CWO) nanoparticles (NPs) are encapsulated within a biocompatible poly(ethylene glycol-b-d,l-lactic acid) (PEG-PLA) block copolymer (BCP) capsule. We show that these PEG-PLA-encapsulated CWO NPs (170 ± 10 nm hydrodynamic diameter) produce a higher CT contrast (by a factor of about 2) than commercial iodine-based radiocontrast agents (e.g., Iohexol) at identical molar concentrations of W or I atoms. PEG-PLA-coated CWO NPs are chemically stable and completely nontoxic. It was confirmed that the maximum tolerated dose (MTD) of this material in mice is significantly higher (250 ± 50 mg per kg body weight following a single intravenous (IV) administration) than, for instance, commercially available dextran-coated iron oxide nanoparticles that are currently used clinically as MRI contrast agents (MTD in mice ≈ 168 mg/kg per dose IV). IV-injected PEG-PLA/CWO NPs caused no histopathologic damage in major excretory organs (heart, liver, lungs, spleen, and kidney). When an IV dose of 100 mg/kg was given to mice, the blood circulation half-life was measured to be about 4 h, and more than 90% of the NPs were cleared from the mice within 24 h via the renal and hepatobiliary systems. When intratumorally administered, PEG-PLA-coated CWO NPs showed complete retention in a tumor-bearing mouse model (measurements were made up to 1 week). These results suggest that PEG-PLA-coated CWO NPs are promising materials for use in CT contrast.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.bioconjchem.6b00451DOI Listing

Publication Analysis

Top Keywords

cwo nps
16
contrast agents
12
peg-pla-coated cwo
12
x-ray computed
8
computed tomography
8
agents x-ray
8
nps
7
contrast
6
x-ray
5
cwo
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!