A mapping technique has been developed where a sub-micrometer focused polychromatic X-ray beam is scanned across a stationary sample instead of scanning the sample in front of the X-ray microbeam. This method is applied to a gold nanowire during its mechanical loading using the tip of an atomic force microscope. During the loading process, such a sample is `accelero-phobic', i.e. the sample scanning stages must not to be moved to avoid parasitic additional load. Without beam scanning, only one single position within the sample can be probed during the test. The probed material point may even change because of drifts or movements induced by the test itself. The new scanning approach facilitates the in situ mapping of the entire wire giving access to the evolution of the wire shape as well as to the boundary conditions. This novel scanning technique opens promising perspectives for studies where sample motion is forbidden because of the sample environment.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S1600577516013849DOI Listing

Publication Analysis

Top Keywords

x-ray beam
8
sample scanning
8
sample
7
scanning
6
scanning x-ray
4
beam laue
4
laue microdiffraction
4
microdiffraction accelero-phobic
4
accelero-phobic samples
4
samples application
4

Similar Publications

Aim: The aim of this cross-sectional prospective study was to evaluate the bone density changes around the bicortical corticobasal implant placed in the maxilla over 18 months of follow-up using cone-beam computed tomography (CBCT), focusing on the comparison between the anterior and posterior teeth and regions.

Materials And Methods: Thirty-five subjects (20, 53.26%, were males, and 15, 46.

View Article and Find Full Text PDF

Aim: This study aimed to evaluate the impact of a combination of immediate implant placement with maxillary sinus augmentation (MSA) solely using platelet-rich fibrin (PRF) on guided bone regeneration.

Materials And Methods: An interventional before-after (pre-post) study design was used with 30 dental patients (≥18 years of age; 14 males and 16 females) with initial bone heights ranging between 4 and 6 mm. Following the general check-up and the creation of a study model, the planned implant location demonstrated an external right maxilla diameter of more than 5 mm, thereby validating the cone-beam computed tomography (CBCT) radiograph.

View Article and Find Full Text PDF

Background: The foramen of Huschke (FH) and the petrotympanic fissure (PTF) are anatomical structures that can influence temporomandibular joint disorders (TMD) by potentially affecting the movement and function of the mandibular condyle.

Objective: This study investigates the relationship between patients with TMD and the presence of FH and PTF to enhance diagnostic and therapeutic approaches.

Methods: This retrospective study analyzed cone beam computed tomography (CBCT) images from 212 patients.

View Article and Find Full Text PDF

Although the modulus of elasticity of the human periodontal ligament (E) values used in dentistry widely ranged from 0.01 to 175 MPa, the exact E value has not been determined. This study aimed to verify whether and how E values affect the stress distribution over the tooth and periodontium structures, and to determine the appropriate E range.

View Article and Find Full Text PDF

Two experimental methods to integrate intra-oral scans into 3D stereophotogrammetric facial images.

Clin Oral Investig

January 2025

Department of Dentistry Section Orthodontics and Craniofacial Biology, Radboud University Medical Center, P.O. Box 9101, Nijmegen, 6500 HB, The Netherlands.

Objectives: For this research two different ways for integrating intra-oral scans into three-dimensional (3D) stereophotogrammetric images are analyzed and compared to the gold standard method.

Materials And Methods: A cross-sectional study was performed. For each patient a complete dataset was collected, which was used to generate 3D fusion models by three different methods: method A using cheek retractors, method B using a tracer and method C using full-skull CBCT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?