Objectives: The precision of localizing the mandibular canal prior to surgical intervention depends on the achievable resolution, whereas identification of the nerve depends on the image contrast. In our study, we developed new protocols based on gradient and spin echo sequences. The results from both sequences were quantitatively compared for their agreement to identify the most suitable approach.
Methods: By limiting the field of view to one side of the mandible, three-dimensional acquisitions with T weighted gradient and spin echo sequences were performed with 0.5 × 0.5 × 0.5 mm resolution within 6.5 min covering the mandibular canal from the mandibular to the mental foramen. Aliasing artefacts were suppressed by different techniques. A manual segmentation of the mandibular canal from seven healthy volunteers was performed on this section by three different observers. The surface distance of the segmented volumes was computed between both sequences as well as between the different observers as a measure of equality.
Results: The quantitative comparison of the segmentation resulted in an average surface distance of 0.26 ± 0.05 mm between both sequences and an interobserver difference of 0.26 ± 0.08 mm for gradient and 0.29 ± 0.07 mm for spin echo data. By repeated evaluation, a difference of 0.15 ± 0.02 mm for gradient and 0.18 ± 0.03 mm for spin echo data was observed, indicating a slightly higher variability for spin echo images.
Conclusions: Both sequences can be used to achieve high-resolution images with good contrast and can be used for precise localization of the mandibular canal. Despite a slightly increased difference for the spin echo data, the advantage of an easy and robust setup remains.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5595013 | PMC |
http://dx.doi.org/10.1259/dmfr.20160268 | DOI Listing |
MAGMA
January 2025
Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Straße 2, 28359, Bremen, Germany.
Objectives: Caffeine, a known neurostimulant and adenosine antagonist, affects brain physiology by decreasing cerebral blood flow. It interacts with adenosine receptors to induce vasoconstriction, potentially disrupting brain homeostasis. However, the impact of caffeine on blood-brain barrier (BBB) permeability to water remains underexplored.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Radiology, Weill Cornell Medicine, New York, NY 10022, USA.
: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.
View Article and Find Full Text PDFNeuroradiology
January 2025
Medical School of Chinese PLA, No.28 Fuxing Road, Haidian District, Beijing, 100853, China.
Purpose: In primary central nervous system lymphoma (PCNSL), B-cell lymphoma-6 (BCL-6) is an unfavorable prognostic biomarker. We aim to non-invasively detect BCL-6 overexpression in PCNSL patients using multiparametric MRI and machine learning techniques.
Methods: 65 patients (101 lesions) with primary central nervous system lymphoma (PCNSL) diagnosed from January 2013 to July 2023, and all patients were randomly divided into a training set and a validation set according to a ratio of 8 to 2.
Tomography
January 2025
NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.
: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.
View Article and Find Full Text PDFCurr Oncol
January 2025
Department of Radiology, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!