Effect of Change in Portal Vein Flow Rates on Hepatic Ablations Created with a Bipolar Radiofrequency Ablation Device.

Radiology

From the Department of Radiology, School of Medicine, University of Colorado, Mail Stop L954, 12401 E 17th Ave, PO Box 6510, Aurora, CO 80045.

Published: May 2017

Purpose To investigate the effect of change in portal vein flow rates on the size and shape of ablations created by a bipolar radiofrequency (RF) ablation device. Materials and Methods This study was exempt from institutional animal care and use committee review. An in vitro bovine liver model perfused with autologous blood via the portal vein at three flow rates (60, 80, 100 mL/min per 100 g of liver) was used. Four ablations, two bipolar and two monopolar (control probe), were made in each of five livers perfused at each flow rate. Short- and long-axis diameters were measured from gross specimens, and volume and sphericity index were calculated for each ablation. A general linear mixed model accounting for correlation within the liver was used to evaluate the effects of flow on ablations. Analyses were performed by using software. Results There was no significant difference in the size or shape of ablations created by the bipolar device at the different flow rates (P > .05 for all outcomes). The monopolar device demonstrated the expected inverse association between ablation size and change in flow (P < .01 for all outcomes). The mean ± standard deviation of short-axis diameter, long-axis diameter, volume, and sphericity index of the bipolar ablations was 4.3 cm ± 0.1, 4.2 cm ± 0.1, 41.0 cm ± 1.8, and 1.1 ± 0.1, respectively. Conclusion Unlike monopolar RF ablation, change in portal vein flow rates does not have a statistically significant effect on the size or shape of ablations created by the bipolar RF ablation device tested. RSNA, 2016.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2016152562DOI Listing

Publication Analysis

Top Keywords

flow rates
20
portal vein
16
ablations created
16
created bipolar
16
change portal
12
vein flow
12
ablation device
12
size shape
12
shape ablations
12
flow
8

Similar Publications

Sex differences in the outcomes of advanced renal cell carcinoma (RCC) treated with immune checkpoint inhibitors (ICIs) and the profiles of tumor-infiltrating immune cells (TIICs) remain unclear. We retrospectively evaluated data from 563 patients with RCC receiving systemic therapy, including first-line dual ICI combinations (i.e.

View Article and Find Full Text PDF

Computational fluid particle dynamics modeling of tangential flow filtration in perfusion cell culture.

Bioprocess Biosyst Eng

January 2025

Cell Culture Development, Biogen, 5000 Davis Drive, Research Triangle Park, NC, 27709, USA.

Membrane fouling is a common and complex challenge with cell culture perfusion process in biopharmaceutical manufacturing that can have detrimental effects on the process performance. In this study, we evaluated a method to calculate the hollow fiber membrane resistance at different time points for water and supernatant. In addition, the number of subvisible particles of < 200 nm.

View Article and Find Full Text PDF

Aim: This study aimed to evaluate the effect of partially edentulous ()PED condition on lung function through spirometry tests and comparison of airflow rates between dentulous and PED subjects.

Settings And Design: The study design was a cross-sectional study conducted in the department of prosthodontics.

Materials And Methods: Twenty-eight dentulous and 28 PED patients with an age range of 25-50 years were included in the study.

View Article and Find Full Text PDF

This cross-sectional study aimed to investigate the role of peak inspiratory flow rate (PIFR) in the management of inhalation therapy for patients with chronic obstructive pulmonary disease (COPD). Conducted in the Department of Pulmonary Medicine at a tertiary care institute from July 2021 to January 2022, this study included a total of 351 patients who were clinically diagnosed with stable COPD and currently receiving inhaler therapy. Participants underwent comprehensive assessments that included demographic data collection, the use of the ABCD assessment tool to evaluate disease severity, the COPD Assessment Test (CAT) for quality of life measurement, and assessments for adherence to inhaler therapy and inhaler technique proficiency.

View Article and Find Full Text PDF

Acute myocardial infarction (AMI) represents a critical health challenge characterized by a significant reduction in blood flow to the heart, leading to high rates of mortality and morbidity. Cardiac troponins, specifically cardiac troponin I and cardiac troponin T, are essential proteins involved in cardiac muscle contraction and serve as vital biomarkers for the diagnosis of AMI. Aptasensors utilize synthetic aptamers or peptides with high affinity for specific biomarkers and offer a promising approach for integration into portable, user-friendly point-of-care (POC) applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!