Purpose: The inverse planning of an intensity-modulated radiation therapy (IMRT) treatment requires decisions regarding the angles used for radiation incidence, even when arcs are used. The possibility of improving the quality of treatment plans by an optimized selection of the beam angle incidences-beam angle optimization (BAO)-is seldom done in clinical practice. The inclusion of noncoplanar beam incidences in an automated optimization routine is even more unusual. However, for some tumor sites, the advantage of considering noncoplanar beam incidences is well known. This paper presents the benefits of using a derivative-free multistart framework for the optimization of the noncoplanar BAO problem.
Methods: Multistart methods combine a global strategy for sampling the search space with a local strategy for improving the sampled solutions. The proposed global strategy allows a thorough exploration of the continuous search space of the highly nonconvex BAO problem. To avoid local entrapment, a derivative-free method is used as local procedure. Additional advantages of the derivative-free method include the reduced number of function evaluations required to converge and the ability to use multithreaded computing. Twenty nasopharyngeal clinical cases were selected to test the proposed multistart framework. The planning target volumes included the primary tumor, the high and low risk lymph nodes. Organs-at-risk included the spinal cord, brainstem, optical nerves, chiasm, parotids, oral cavity, brain, thyroid, among others. For each case, a setup with seven equispaced beams was chosen and the resulting treatment plan, using a multicriteria optimization framework, was then compared against the coplanar and noncoplanar plans using the optimal beam setups obtained by the derivative-free multistart framework.
Results: The optimal noncoplanar beam setup obtained by the derivative-free multistart framework leads to high quality treatment plans with better target coverage and with improved organ sparing compared to treatment plans using equispaced or optimal coplanar beam angle setups. The noncoplanar treatment plans achieved, e.g., an average reduction in the mean dose of the oral cavity of 6.1 Gy and an average reduction in the maximum-dose of the brainstem of 7 Gy when compared to the equispaced treatment plans.
Conclusions: The noncoplanar BAO problem is an extremely challenging multimodal optimization problem that can be successfully addressed through a thoughtful exploration of the continuous highly nonconvex BAO search space. The proposed framework is capable of calculating high quality treatment plans and thus can be an interesting alternative toward automated noncoplanar beam selection in IMRT treatment planning which is nowadays the natural trend in treatment planning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.4962477 | DOI Listing |
J Radiat Res
January 2025
Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi, 466-8550, Japan.
Dynamic WaveArc (DWA) is a technique used for continuous, non-coplanar volumetric-modulated arc therapy on the Vero4DRT platform. This study aimed to evaluate the application of single-isocenter DWA (SI-DWA) for treating multiple brain metastases by comparing dose distribution and irradiation time with multi-isocenter DWA (MI-DWA) through retrospective treatment planning. Treatment plans were developed for SI-DWA and MI-DWA in 14 cases with 3-5 brain metastases.
View Article and Find Full Text PDFCureus
November 2024
Medical Physics, BC Cancer Kelowna, Kelowna, CAN.
Linac-based stereotactic radiosurgery (SRS) with planning target volume (PTV) margins <1 mm has become increasingly common in recent years. Optical surface imaging for surface-guided radiation therapy (SGRT) is often used for intra-fraction motion monitoring during these treatments to facilitate the use of a smaller PTV margin by providing real-time quantitative patient positioning information. However, rotating the couch introduces errors to SGRT-reported translations and rotations that can be problematic for SRS treatments with non-coplanar arcs and very small PTV margins.
View Article and Find Full Text PDFJpn J Radiol
November 2024
Department of Physics, School of Advanced Sciences, Vellore Institute of Technology (VIT), Chennai Campus, Vandalur - Kelambakkam Road, Chennai, Tamil Nadu, 600 127, India.
Purpose: To optimize NTO parameters in non-coplanar RapidArc (RA) stereotactic radiosurgery (SRS) for multiple brain metastases and compare them with HyperArc (HA) plans.
Materials And Methods: Thirty patients with multiple brain metastases, receiving 21 Gy prescriptions, were retrospectively enrolled, with lesions ranging from two to eight and volumes between 0.27 and 10.
Med Phys
January 2025
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.
Background: Non-coplanarity and mixed beam modality could be combined to further enhance dosimetric treatment plan quality. We introduce dynamic mixed beam arc therapy (DYMBARC) as an innovative technique that combines non-coplanar photon and electron arcs, dynamic gantry and collimator rotations, and intensity modulation with photon multileaf collimator (MLC). However, finding favorable beam directions for DYMBARC is challenging due to the large solution space, machine component constraints, and optimization parameters, posing a highly non-convex optimization problem.
View Article and Find Full Text PDFCureus
August 2024
Department of Radiology, Aichi Medical University, Nagakute, JPN.
Introduction In linac-based stereotactic radiosurgery (SRS) leveraging a multileaf collimator (MLC) for brain metastasis (BM), volumetric-modulated arcs (VMAs) enable the generation of a suitable dose distribution with efficient planning and delivery. However, the arc arrangement, including the number of arcs, allocation, and rotation ranges, varies substantially among devices and facilities. Some modalities allow coplanar arc(s) (CA(s)) or beam(s) alone, and some facilities only use them intentionally despite the availability of non-coplanar arcs (NCAs).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!