Purpose: The positive predictive power for malignancy can potentially be improved, if the chemical compositions of suspicious breast lesions can be reliably measured in screening mammography. The purpose of this study is to investigate the feasibility of quantifying breast lesion composition, in terms of water and lipid contents, with spectral mammography.

Methods: Phantom and tissue samples were imaged with a spectral mammography system based on silicon-strip photon-counting detectors. Dual-energy calibration was performed for material decomposition, using plastic water and adipose-equivalent phantoms as the basis materials. The step wedge calibration phantom consisted of 20 calibration configurations, which ranged from 2 to 8 cm in thickness and from 0% to 100% in plastic water density. A nonlinear rational fitting function was used in dual-energy calibration of the imaging system. Breast lesion phantoms, made from various combinations of plastic water and adipose-equivalent disks, were embedded in a breast mammography phantom with a heterogeneous background pattern. Lesion phantoms with water densities ranging from 0% to 100% were placed at different locations of the heterogeneous background phantom. The water density in the lesion phantoms was measured using dual-energy material decomposition. The thickness and density of the background phantom were varied to test the accuracy of the decomposition technique in different configurations. In addition, an in vitro study was also performed using mixtures of lean and fat bovine tissue of 25%, 50%, and 80% lean weight percentages as the background. Lesions were simulated by using breast lesion phantoms, as well as small bovine tissue samples, composed of carefully weighed lean and fat bovine tissues. The water densities in tissue samples were measured using spectral mammography and compared to measurement using chemical decomposition of the tissue.

Results: The thickness of measured and known water contents was compared for various lesion configurations. There was a good linear correlation between the measured and the known values. The root-mean-square errors in water thickness measurements were 0.3 and 0.2 mm for the plastic phantom and bovine tissue backgrounds, respectively.

Conclusions: The results indicate that spectral mammography can be used to accurately characterize breast lesion composition in terms of their equivalent water and lipid contents.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5035310PMC
http://dx.doi.org/10.1118/1.4962481DOI Listing

Publication Analysis

Top Keywords

breast lesion
20
spectral mammography
16
lesion phantoms
16
tissue samples
12
plastic water
12
bovine tissue
12
water
10
lesion
8
lesion composition
8
composition terms
8

Similar Publications

A Phase II Trial of Onapristone and Fulvestrant for Patients With ER+ and HER2- Metastatic Breast Cancer.

Clin Breast Cancer

December 2024

Medical Oncology and Palliative Care, Department of Medicine, Breast Cancer Disease Oriented Team, University of Wisconsin Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792-3252.

Background: The SMILE study is a multi-institutional phase II clinical trial to determine the efficacy and safety of an antiprogestin, onapristone, in combination with fulvestrant as second-line therapy for patients with ER+, PgR+/-, HER2- metastatic breast cancer. This study was terminated early and herein, we report patient characteristics, and outcomes.

Methods: Eligibility criteria included disease progression on ≥2 lines of prior therapy, ECOG performance status ≤ 2, measurable disease per RECIST 1.

View Article and Find Full Text PDF

Background: Intraoperative ultrasound-guided breast-conserving surgery guarantees real-time direct visualization of tumor and resection margins. We compared surgical, oncologic, and cosmetic outcomes between intraoperative ultrasound-guided breast-conserving surgery and traditional (palpation- or wire-guided) surgery across all breast cancer lesion types.

Methods: This prospective observational cohort study was conducted at the Veneto Institute of Oncology between January 2021 and October 2022.

View Article and Find Full Text PDF

Contrast-enhanced ultrasonography (CEUS), a newly developed imaging technique, holds certain value in differentiating benign from malignant tumors. Additionally, serum tumor markers also exhibit significant clinical importance in the diagnosis and monitoring of malignant tumors. Reports have indicated abnormal expression of HER-2, CA153 and sE-cad in breast cancer.

View Article and Find Full Text PDF

Introduction: Basal cell carcinoma (BCC) is the most common type of skin malignancy, accounting for approximately 80% of all non-melanoma skin cancers (NMSCs). Ultraviolet (UV) exposure is a significant risk factor for BCC development, which typically occurs in sun-exposed areas. BCC arising in non-sun-exposed regions, such as the nipple-areola complex (NAC), is exceedingly rare, with fewer than 100 cases reported globally.

View Article and Find Full Text PDF

Acrometastasis is an extremely rare diagnosis, invariably associated with poor prognosis. A 60-year-old female with complaints of cough and breathing difficulty also presented with pain and swelling in her left leg. Radiological investigations suggested a double primary in the lung and leg; histopathology and immunohistochemistry (IHC) confirmed the lesion in the leg to be metastatic from the lung primary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!