The effects of aorto-femoral bypass grafts on the vascular input impedance, and the ratio of pulsatile to total power were studied in eight dogs. Unilateral ileo-femoral stenosis was simulated and comparisons were made between the input impedance and power distribution in healthy and simulated disease situations. Input impedance magnitude spectra and phase were displayed graphically and it was shown that the presence of the simulated disease increases the ratio of pulsatile to total power as measured in the abdominal aorta from 7.5 to 14.8% (p less than 0.05). This suggests that the presence of the stenosis creates an impedance mismatch thus causing reflected waves to propagate proximally towards the heart. It was concluded that the way in which the heart transfers fluid power into the arterial bed was compromised by the presence of the ileo-femoral partial stenoses. It is further suggested that the system described in the paper makes it possible to quantitatively assess afterload, vascular input impedance and cardiovascular power distribution as a quasi-real time diagnostic procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0021-9290(89)90205-4 | DOI Listing |
Food Chem
January 2025
College of Engineering, China Agricultural University, Beijing 100083, PR China. Electronic address:
Efficient, non-destructive and real-time meat freshness assessment has always been a hot research topic. This paper presents a novel approach for detecting lamb meat freshness using a flexible optoelectronic sensing system combined with an integrated learning model. We developed a flexible impedance sensing system and a flexible optical sensing system through laser direct writing and transfer technology.
View Article and Find Full Text PDFBiomed Microdevices
January 2025
Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA.
Wearable and implantable biosensors have rapidly entered the fields of health and biomedicine to diagnose diseases and physiological monitoring. The use of wired medical devices causes surgical complications, which can occur when wires break, become infected, generate electrical noise, and are incompatible with implantable applications. In contrast, wireless power transfer is ideal for biosensing applications since it does not necessitate direct connections between measurement tools and sensing systems, enabling remote use of the biosensors.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Faculty of Engineering Science, University of Bayreuth, 95440 Bayreuth, Germany.
Molding sand mixtures in the foundry industry are typically composed of fresh and reclaimed sands, water, and additives such as bentonite. Optimizing the control of these mixtures and the recycling of used sand after casting requires an efficient in-line monitoring method, which is currently unavailable. This study explores the potential of an AI-enhanced electrical impedance spectroscopy (EIS) system as a solution.
View Article and Find Full Text PDFSensors (Basel)
December 2024
State Key Discipline Laboratory of Wide Bandgap Semiconductor Technology, School of Microelectronics, Xidian University, Xi'an 710071, China.
This paper presents a 35 nV/√Hz analog front-end (AFE) circuitdesigned in the UMC 40 nm CMOS technology for the acquisition of biopotential signal. The proposed AFE consists of a capacitive-coupled instrumentation amplifier (CCIA) and a combination of a programmable gain amplifier (PGA) and a low-pass filter (LPF). The CCIA includes a DC servo loop (DSL) to eliminate electrode DC offset (EDO) and a ripple rejection loop (RRL) with self-zeroing technology to suppress high-frequency ripples caused by the chopper.
View Article and Find Full Text PDFACS Nano
January 2025
School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Republic of Singapore.
Hydrogel-based sensors have been widely studied for perceiving the environment. However, the simplest type of resistive sensors still lacks sensitivity to localized strain and other extractable data. Enhancing their sensitivity and expanding their functionality to perceive multiple stimuli simultaneously are highly beneficial yet require optimal material design and proper testing methods.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!