A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Some aspects of space-charge effect calculation in high-resolution mass spectrometry. | LitMetric

Some aspects of space-charge effect calculation in high-resolution mass spectrometry.

J Chromatogr B Analyt Technol Biomed Life Sci

ООО "Аdvanced Energy Technologies", ul. Novaya 100, Skolkovo, Moscow region, 143025 Russia; Institute for Energy Problems of Chemical Physics, Russian Academy of Sciences, P.O.B. 56 Chernogolovka, Moscow region, 142432 Russia.

Published: March 2017

A variational 3D approach to the problem of simulating stationary distributions of ions in the radiofrequency low-vacuum ion traps with regard to Coulomb interaction and collisions of ions with buffer gas molecules is proposed. The software developed in the course of this work is employed to study the structure of stationary ion ensembles in the radiofrequency ion traps of various types. The effect of high-frequency and constant voltages, space-charge density, and buffer gas temperature on the formation of stationary distributions in the radiofrequency ion traps and their limiting capacitance is investigated. It is shown that the use of electrodes with a constant voltage in the presence of high enough ion density allows pre-filtering of ions directly in a high-frequency trap-accumulator.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2016.09.031DOI Listing

Publication Analysis

Top Keywords

ion traps
12
stationary distributions
8
buffer gas
8
radiofrequency ion
8
ion
5
aspects space-charge
4
space-charge calculation
4
calculation high-resolution
4
high-resolution mass
4
mass spectrometry
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!