An investigation into corneal enzymatic resistance following epithelium-off and epithelium-on corneal cross-linking protocols.

Exp Eye Res

Structural Biophysics Research Group, School of Optometry and Vision Sciences, Cardiff University, Maindy Road, Cardiff, CF24 4HQ, UK. Electronic address:

Published: December 2016

The aim of this study was to investigate corneal enzymatic resistance following epithelium off and on riboflavin/UVA cross-linking (CXL). One hundred and fourteen porcine eyes were divided into four non-irradiated control groups and seven CXL groups. The latter comprised; (i) epithelium-off, 0.1% iso-osmolar riboflavin, 9 mW UVA irradiation for 10 min, (ii) disrupted epithelium, 0.1% hypo-osmolar riboflavin, 9 mW UVA for 10 min, (iii) epithelium-on, 0.25% hypo-osmolar riboflavin with 0.01% benzylalkonium chloride (BACS), 9 mW UVA for 10 min, (iv) epithelium-on, 5 min iontophoresis at 0.1 mA for 5 min with 0.1% riboflavin solution, 9 mW UVA for 10 min or (v) 12.5 min, (vi) epithelium-on, prolonged iontophoresis protocol of 25 min with 1.0 mA for 5 min and 0.5 mA for 5 min with 0.25% riboflavin with 0.01% BACS, 9 mW UVA for 10 min or (vii) 12.5 min. Enzymatic resistance was assessed by daily measurement of a corneal button placed in pepsin solution and measurement of corneal button dry weight after 11 days of digestion. This study revealed that the enzymatic resistance was greater in CXL corneas than non-irradiated corneas (p < 0.0001). Epithelium-off CXL showed the greatest enzymatic resistance (p < 0.0001). The prolonged iontophoresis protocol was found to be superior to all other trans-epithelial protocols (p < 0.0001). A 25% increase in UVA radiance significantly increased corneal enzymatic resistance (p < 0.0001). In conclusion, although epithelium-on CXL appears to be inferior to epithelium-off CXL in terms of enzymatic resistance to pepsin digestion, the outcome of epithelium-on CXL may be significantly improved through the use of higher concentrations of riboflavin solution, a longer duration of iontophoresis and an increase in UVA radiance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5131611PMC
http://dx.doi.org/10.1016/j.exer.2016.10.014DOI Listing

Publication Analysis

Top Keywords

9 mw uva
20
enzymatic resistance
16
uva 10 min
16
corneal enzymatic
8
riboflavin 9 mw
8
hypo-osmolar riboflavin
8
riboflavin 001%
8
bacs 9 mw
8
measurement corneal
8
corneal button
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!