Objectives: To compare the diagnostic efficacies of B-mode ultrasound (US), strain elastography (SE), contrast-enhanced ultrasound (CEUS) and the combination of these modalities for breast lesions <1 cm in size.

Methods: Between January 2013 and October 2015, 203 inpatients with 209 sub-centimetre breast lesions categorised as BI-RADS-US (Breast Imaging Reporting and Data System for Ultrasound) 3-5 were included. US, SE and CEUS were performed to evaluate each lesion. The diagnostic performances of different ultrasonic modalities were compared. The diagnostic efficacies of BI-RADS-US and our re-rating systems were also compared. The pathology findings were used as the reference standard.

Results: The specificities of US, SE and CEUS for tumour differentiation were 17.4 %, 56.2 % and 86.0 %, respectively (P < 0.05); and the sensitivities were 100 %, 93.2 % and 93.2 % for US, SE and CEUS, respectively (P < 0.05). The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was 0.867 for original BI-RADS-US, 0.882 for BI-RADS-US combined with only SE, 0.953 for BI-RADS-US combined with only CEUS and 0.924 for BI-RADS-US combined with both SE and CEUS. The best combination was BI-RADS-US combined with only CEUS.

Conclusions: Evaluating sub-centimetre breast lesions with SE and CEUS could increase the diagnostic specificity while retaining high sensitivity compared with B-mode ultrasound.

Key Points: • Evaluating breast lesions with SE and CEUS could increase the diagnostic specificity • SE and CEUS offer alternatives to biopsy and possibly allow shorter-interval follow-ups • BI-RADS-US combined with CEUS exhibited the best diagnostic performance.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-016-4628-4DOI Listing

Publication Analysis

Top Keywords

breast lesions
8
strain elastography
8
elastography contrast-enhanced
8
diagnosis sub-centimetre
4
sub-centimetre breast
4
lesions combining
4
combining bi-rads-us
4
bi-rads-us strain
4
contrast-enhanced ultrasound-a
4
ultrasound-a preliminary
4

Similar Publications

: This study aimed to evaluate the diagnostic performance of the Kaiser score (KS) on the modified abbreviated breast magnetic resonance imaging (AB-MRI) protocol for characterizing breast lesions by comparing it with full-protocol MRI (FP-MRI), using the histological data as the reference standard. : Breast MRIs detecting histologically verified contrast-enhancing breast lesions were evaluated retrospectively. A modified AB-MRI protocol was created from the standard FP-MRI, which comprised axial fat-suppressed T2-weighted imaging (T2WI), pre-contrast T1-weighted imaging (T1WI), and first, second, and fourth post-contrast phases.

View Article and Find Full Text PDF

Assessing Malignant Risk in B3 Breast Lesions: Clinical Insights and Implications.

J Clin Med

December 2024

Multidisciplinary Breast Centre, Dipartimento Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy.

: B3 breast lesions, characterized by uncertain malignant potential, pose a significant challenge for clinicians. With the increasing use of preoperative biopsies, there is a need for careful management strategies, including watchful waiting, vacuum-assisted excision (VAE), and surgery. This study aims to assess the concordance between preoperative biopsy findings and postoperative histology, with a focus on evaluating the positive predictive value (PPV) for malignancy in B3 lesions.

View Article and Find Full Text PDF

The growing interest in minimal and non-invasive therapies, especially in the field of cancer treatment, highlights a significant shift toward safer and more effective options. Ablative therapies are well-established tools in cancer treatment, with known effects including locoregional control, while their role as modulators of the systemic immune response against cancer is emerging. The HIFU developed with magnetic resonance imaging (MRI) guidance enables treatment precision, improves real-time procedural control, and ensures accurate outcome assessment.

View Article and Find Full Text PDF
Article Synopsis
  • The study examined if ADC map values of breast lesions with non-mass enhancement on MRI could distinguish between benign and malignant cases.
  • A total of 136 patients underwent ultrasound-guided biopsies, and radiologists measured ADC values independently, comparing results to pathology reports.
  • The whole tumor region of interest (ROI) showed the highest sensitivity at 91% for detecting benign lesions, while there were no significant ADC value differences between fatty and dense breast tissues.
View Article and Find Full Text PDF

Contrast-enhanced mammography (CEM) has recently gained recognition as an effective alternative to breast magnetic resonance imaging (MRI) for assessing breast lesions, offering both morphological and functional imaging capabilities. However, the phenomenon of background parenchymal enhancement (BPE) remains a critical consideration, as it can affect the interpretation of images by obscuring or mimicking lesions. While the impact of BPE has been well-documented in MRI, limited data are available regarding the factors influencing BPE in CEM and its relationship with breast cancer (BC) characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!