A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bioanalytical Method Validation for Dronedarone and Duloxetine in Blood Serum. | LitMetric

Bioanalytical Method Validation for Dronedarone and Duloxetine in Blood Serum.

J AOAC Int

Punjabi University, Department of Pharmaceutical Sciences and Drug Research, Patiala, Punjab 147002, India.

Published: January 2017

The present work relates to the development and validation of reversed-phase HPLC-UV-photodiode array methods for the estimation of two drugs in blood serum: dronedarone hydrochloride (DDN), a class III antiarrhythmic drug, and duloxetine hydrochloride (DLX), an antidepressant. Chromatographic analysis of DLX was carried out on a Nucleodur C18 column (250 × 4.6 mm, 5 μm) using ammonium acetate buffer (32 mM, pH 5.5) and acetonitrile (40 + 60, v/v; flow rate of 1.0 mL/min; detection wavelength of 290 nm) as the mobile phase. A Waters XTerra C18 column (250 × 4.6 mm, 5 μm) was used for the chromatographic analysis of DDN using an acetonitrile-ammonium formate buffer (20 mM, pH 3.0, with formic acid; 45 + 55, v/v; flow rate 1.0 mL/min) as the mobile phase. Pentazocine and bupropion HCl were used as the internal reference standards for DLX and DDN, respectively. Excellent linearity was observed for DLX (r2 = 0.9996; concentration range 0.2-10.0 μg/mL) and DDN (r2 = 0.9997; concn. range 2.0-50.0 μg/mL). The LODs for DLX and DDN were 0.022 and 0.78 μg/mL, respectively, and the LOQs 0.066 and 2.4 μg/mL, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.5740/jaoacint.16-0204DOI Listing

Publication Analysis

Top Keywords

blood serum
8
chromatographic analysis
8
c18 column
8
column 250
8
250 μm
8
v/v flow
8
flow rate
8
rate ml/min
8
mobile phase
8
dlx ddn
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!