In spite of recent advances in treatment protocols, tendinopathies continue to challenge orthopaedists and surgeons. Due to the complexity of both tendon injuries and the healing processes, animal models are essential for addressing fundamental questions in tendinopathy research. Diagnostic imaging could contribute to the evaluation of animal models, thus providing information, which could be translated to human tendinopathies. The objective of our study was to evaluate in situ appearance of the rabbit common calcanean tendon with ultrasonography and magnetic resonance imaging. Additionally, we sought to assess and compare the feasibility and usefulness of these techniques in a rabbit model while focusing on the imaging of the particular structures involved in calcaneal tendon disorders. Eight California rabbits were used for post-mortem sonographic and low-field magnetic resonance examination. Morphometry was performed on longitudinal sonograms and sagittal MRI scans. The craniocaudal diameter of the tendon was measured at four points of interest. Ultrasonography and magnetic resonance provided good visualisation of the tendon origin, the paratenon and the pre-Achilles fat pad. Magnetic resonance images presented in more detail the structure of the calcaneal insertion. Both modalities failed to visualise the individual components of the common calcanean tendon and the bursa of the calcaneal tendon. Statistical analysis of measurements obtained showed that the craniocaudal diameter of the common calcanean tendon in a rabbit increases significantly with a growing length from the calcaneal tuber. Both magnetic resonance and ultrasonography are feasible, and should be considered complementary, not alternative imaging techniques in a rabbit common calcanean tendon model.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/pjvs-2016-0066 | DOI Listing |
JCO Clin Cancer Inform
January 2025
Machine Learning Department, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL.
Purpose: Adaptive radiotherapy accounts for interfractional anatomic changes. We hypothesize that changes in the gross tumor volumes identified during daily scans could be analyzed using delta-radiomics to predict disease progression events. We evaluated whether an auxiliary data set could improve prediction performance.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Hospital Universitario HM Montepríncipe, HM Hospitales. Facultad HM. Hospitales de Ciencias de la Salud, Universidad Camilo José Cela, Madrid, Spain.
PLoS One
January 2025
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Department of Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, Connecticut.
Case: A 16-year-old woman presented with acute on chronic knee pain and instability following a twisting injury. The tibial insertion of the anterior cruciate ligament (ACL) was nonvisualized on magnetic resonance imaging. A cord-like ACL, originating from the lateral intercondylar notch and inserting smoothly into the anterior horn of the intact lateral meniscus, was found on arthroscopy.
View Article and Find Full Text PDFSci Adv
January 2025
Department of Biostatistics, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
Genes on the X chromosome are extensively expressed in the human brain. However, little is known for the X chromosome's impact on the brain anatomy, microstructure, and functional networks. We examined 1045 complex brain imaging traits from 38,529 participants in the UK Biobank.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!