Background: The genetic basis of atrial fibrillation (AF) and congenital heart disease remains incompletely understood.
Objective: We sought to determine the causative mutation in a family with AF, atrial septal defects, and ventricular septal defects.
Methods: We evaluated a pedigree with 16 family members, 1 with an atrial septal defect, 1 with a ventricular septal defect, and 3 with AF; we performed whole exome sequencing in 3 affected family members. Given that early-onset AF was prominent in the family, we then screened individuals with early-onset AF, defined as an age of onset <66 years, for mutations in GATA6. Variants were functionally characterized using reporter assays in a mammalian cell line.
Results: Exome sequencing in 3 affected individuals identified a conserved mutation, R585L, in the transcription factor gene GATA6. In the Massachusetts General Hospital Atrial Fibrillation (MGH AF) Study, the mean age of AF onset was 47.1 ± 10.9 years; 79% of the participants were men; and there was no evidence of structural heart disease. We identified 3 GATA6 variants (P91S, A177T, and A543G). Using wild-type and mutant GATA6 constructs driving atrial natriuretic peptide promoter reporter, we found that 3 of the 4 variants had a marked upregulation of luciferase activity (R585L: 4.1-fold, P < .0001; P91S: 2.5-fold, P = .0002; A177T; 1.7-fold, P = .03). In addition, when co-overexpressed with GATA4 and MEF2C, GATA6 variants exhibited upregulation of the alpha myosin heavy chain and atrial natriuretic peptide reporter activity.
Conclusion: Overall, we found gain-of-function mutations in GATA6 in both a family with early-onset AF and atrioventricular septal defects as well as in a family with sporadic, early-onset AF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hrthm.2016.10.014 | DOI Listing |
J Cardiol
January 2025
Department of Cardiology, St. Luke's University Health Network, Bethlehem, PA, USA. Electronic address:
Background: Hypertrophic cardiomyopathy (HCM) is a common genetic disease with estimated prevalence of 0.2-0.5 %.
View Article and Find Full Text PDFJ Cardiol
January 2025
Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Background: Delirium is associated with patient prognosis after transcatheter aortic valve implantation (TAVI). However, the prognostic impact of subsyndromal delirium, described as an intermediate stage between delirium and normal cognition, is uncertain. The present study aimed to investigate the prognostic impact of delirium severity in patients undergoing TAVI.
View Article and Find Full Text PDFJ Cardiol
January 2025
Arrhythmia Diagnosis and Treatment Center, The First Affiliated Hospital of Ningbo University, Ningbo, China. Electronic address:
Background: Although the method of autocalibration or calibration based on catheter diameters was proposed for fluoroscopic measurement during percutaneous left atrial appendage occlusion (LAAO), it may be imprecise and lead to mismeasurement. We sought to investigate whether the utilization of the surface steel ball calibration (SSBC) method under fluoroscopy could facilitate the fluoroscopic measurement of the post-implanted WATCHMAN device (Boston Scientific Corporation, Natick, MA, USA) in LAAO.
Methods: This retrospective study included 97 consecutive patients who underwent percutaneous LAAO with the WATCHMAN device.
J Cardiovasc Electrophysiol
January 2025
McGill University Health Centre, Montreal, Canada.
Background: Electrographic flow (EGF) mapping allows for the visualization of global atrial wavefront propagations. One mechanism of initiation and maintenance of atrial fibrillation (AF) is stimulation from EGF-identified focal sources that serve as driver sites of fibrillatory conduction. Electrographic flow consistency (EGFC) further quantifies the concordance of observed wavefront patterns, indicating that a healthier substrate shows more organized wavefront propagation and higher EGFC.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!