Genomic Adequacy from Solid Tumor Core Needle Biopsies of ex Vivo Tissue and in Vivo Lung Masses: Prospective Study.

Radiology

From the Departments of Radiological Sciences (N.J., D.H., F.G.A., C.T.L., S.T.K., R.D.S., S.Y., D.R.E., M.D.K.) and Pathology (S.Y., K.D., S.D., S.B., M.D.K.), David Geffen School of Medicine at UCLA, 10833 LeConte Ave, Box 951721, CHS 17-135, Los Angeles, CA 90095-1721.

Published: March 2017

Purpose To identify the variables and factors that affect the quantity and quality of nucleic acid yields from imaging-guided core needle biopsy. Materials and Methods This study was approved by the institutional review board and compliant with HIPAA. The authors prospectively obtained 232 biopsy specimens from 74 patients (177 ex vivo biopsy samples from surgically resected masses were obtained from 49 patients and 55 in vivo lung biopsy samples from computed tomographic [CT]-guided lung biopsies were obtained from 25 patients) and quantitatively measured DNA and RNA yields with respect to needle gauge, number of needle passes, and percentage of the needle core. RNA quality was also assessed. Significance of correlations among variables was assessed with analysis of variance followed by linear regression. Conditional probabilities were calculated for projected sample yields. Results The total nucleic acid yield increased with an increase in the number of needle passes or a decrease in needle gauge (two-way analysis of variance, P < .0001 for both). However, contrary to calculated differences in volume yields, the effect of needle gauge was markedly greater than the number of passes. For example, the use of an 18-gauge versus a 20-gauge biopsy needle resulted in a 4.8-5.7 times greater yield, whereas a double versus a single pass resulted in a 2.4-2.8 times greater yield for 18- versus 20-gauge needles, respectively. Ninety-eight of 184 samples (53%) had an RNA integrity number of at least 7 (out of a possible score of 10). Conclusion With regard to optimizing nucleic acid yields in CT-guided lung core needle biopsies used for genomic analysis, there should be a preference for using lower gauge needles over higher gauge needles with more passes. RSNA, 2016 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 21, 2016.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2016132230DOI Listing

Publication Analysis

Top Keywords

core needle
12
nucleic acid
12
needle gauge
12
needle
10
needle biopsies
8
vivo lung
8
acid yields
8
biopsy samples
8
number needle
8
needle passes
8

Similar Publications

A prospective, phase II, neoadjuvant study based on chemotherapy sensitivity in HR+/HER2- breast cancer-FINEST study.

Cancer Commun (Lond)

January 2025

Department of Breast Surgery, Key Laboratory of Breast Cancer in Shanghai, Fudan University Shanghai Cancer Centre, Shanghai, P. R. China.

Background: Hormone receptor-positive (HR+)/humaal growth factor receptor 2-negative (HER2-) breast cancer, the most common breast cancer type, has variable prognosis and high recurrence risk. Neoadjuvant therapy is recommended for median-high risk HR+/HER2- patients. This phase II, single-arm, prospective study aimed to explore appropriate neoadjuvant treatment strategies for HR+/HER2- breast cancer patients.

View Article and Find Full Text PDF

Evaluation of an enhanced ResNet-18 classification model for rapid On-site diagnosis in respiratory cytology.

BMC Cancer

January 2025

Department of Pathology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.

Objective: Rapid on-site evaluation (ROSE) of respiratory cytology specimens is a critical technique for accurate and timely diagnosis of lung cancer. However, in China, limited familiarity with the Diff-Quik staining method and a shortage of trained cytopathologists hamper utilization of ROSE. Therefore, developing an improved deep learning model to assist clinicians in promptly and accurately evaluating Diff-Quik stained cytology samples during ROSE has important clinical value.

View Article and Find Full Text PDF

Imaging-guided percutaneous core needle biopsy (PCNB) is currently the most common technique for the investigation of potentially malignant bone lesions. It allows precise needle placement and better visual guidance, leading to improved diagnostic accuracy. Needle tract seeding (NTS) is a rare complication of biopsies in general, and its true incidence remains unknown.

View Article and Find Full Text PDF

Background: Flat epithelial atypia (FEA), a rare breast proliferative lesion, is often diagnosed following core biopsy (CB) of mammographic microcalcifications. In the prospective multi-institution TBCRC 034 trial, we investigate the upgrade rate to ductal carcinoma in situ (DCIS) or invasive cancer following excision for patients diagnosed with FEA on CB.

Patients And Methods: Patients with a breast imaging reporting and data system (BI-RADS) ≤ 4 imaging abnormality and a concordant CB diagnosis of FEA were identified for excision.

View Article and Find Full Text PDF

Purpose: This study aimed to investigate the usefulness of ultrasound-guided core-needle biopsy (US-CNB) for diagnosing type 1 AIP and evaluate the radiological outcomes following steroid therapy.

Materials And Methods: From January 2017 to June 2023, patients with pathology results containing "lymphoplasmacytic infiltration" and "fibrosis" were enrolled. The detection rate of level 1 histology by International Consensus Diagnostic Criteria (ICDC) and the contribution of US-CNB were assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!