AI Article Synopsis

  • - This study focuses on harmonizing diffusion MRI (dMRI) images across different sites to improve neuroimaging research by increasing sample size and statistical power.
  • - The proposed method uniquely accounts for varying brain signal characteristics across locations instead of using a single statistical model, and it operates without assuming a specific diffusion model.
  • - Validation of the method involved analyzing dMRI data from four different scanners, showing that it effectively removes scanner-related differences while retaining the integrity of diffusion measures like fractional anisotropy and mean diffusivity.

Article Abstract

Harmonizing diffusion MRI (dMRI) images across multiple sites is imperative for joint analysis of the data to significantly increase the sample size and statistical power of neuroimaging studies. In this work, we develop a method to harmonize diffusion MRI data across multiple sites and scanners that incorporates two main novelties: i) we take into account the spatial variability of the signal (for different sites) in different parts of the brain as opposed to existing methods, which consider one linear statistical covariate for the entire brain; ii) our method is model-free, in that no model of diffusion (e.g., tensor, compartmental models, etc.) is assumed and the signal itself is corrected for scanner related differences. We use spherical harmonic basis functions to represent the signal and compute several rotation invariant features, which are used to estimate a regionally specific linear mapping between signal from different sites (and scanners). We validate our method on diffusion data acquired from four different sites (including two GE and two Siemens scanners) on a group of healthy subjects. Diffusion measures such fractional anisotropy, mean diffusivity and generalized fractional anisotropy are compared across multiple sites before and after the mapping. Our experimental results demonstrate that, for identical acquisition protocol across sites, scanner-specific differences can be accurately removed using the proposed method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5045042PMC
http://dx.doi.org/10.1007/978-3-319-24553-9_2DOI Listing

Publication Analysis

Top Keywords

multiple sites
16
diffusion mri
12
sites scanners
12
harmonizing diffusion
8
mri data
8
data multiple
8
sites
8
signal sites
8
fractional anisotropy
8
diffusion
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!