Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Wearable sweat biosensensing technology has dominantly relied on techniques which place planar-sensors or fluid-capture materials directly onto the skin surface. This 'on-skin' approach can result in sample volumes in the μL regime, due to the roughness of skin and/or due to the presence of hair. Not only does this increase the required sampling time to 10's of minutes or more, but it also increases the time that sweat spends on skin and therefore increases the amount of analyte contamination coming from the skin surface. Reported here is a first demonstration of a new paradigm in sweat sampling and sensing, where sample volumes are reduced from the μL's to nL's regime, and where analyte contamination from skin is reduced or even eliminated. A micro-porous membrane is constructed such that it is porous to sweat only. To complete a working device, first placed onto skin is a cosmetic-grade oil, secondly this membrane, and thirdly the sensors. As a result, spreading of sweat is isolated to only regions above the sweat glands before it reaches the sensors. Best case sampling intervals are on the order of several minutes, and the majority of hydrophilic (low oil solubility) contaminants from the skin surface are blocked. In vitro validation of this new approach is performed with an improved artificial skin including human hair. In vivo tests show strikingly consistent results, and reveal that the oil/membrane is robust enough to even allow horizontal sliding of a sensor.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c6lc01013j | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!