Wearable sweat biosensensing technology has dominantly relied on techniques which place planar-sensors or fluid-capture materials directly onto the skin surface. This 'on-skin' approach can result in sample volumes in the μL regime, due to the roughness of skin and/or due to the presence of hair. Not only does this increase the required sampling time to 10's of minutes or more, but it also increases the time that sweat spends on skin and therefore increases the amount of analyte contamination coming from the skin surface. Reported here is a first demonstration of a new paradigm in sweat sampling and sensing, where sample volumes are reduced from the μL's to nL's regime, and where analyte contamination from skin is reduced or even eliminated. A micro-porous membrane is constructed such that it is porous to sweat only. To complete a working device, first placed onto skin is a cosmetic-grade oil, secondly this membrane, and thirdly the sensors. As a result, spreading of sweat is isolated to only regions above the sweat glands before it reaches the sensors. Best case sampling intervals are on the order of several minutes, and the majority of hydrophilic (low oil solubility) contaminants from the skin surface are blocked. In vitro validation of this new approach is performed with an improved artificial skin including human hair. In vivo tests show strikingly consistent results, and reveal that the oil/membrane is robust enough to even allow horizontal sliding of a sensor.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c6lc01013jDOI Listing

Publication Analysis

Top Keywords

sample volumes
12
analyte contamination
12
skin surface
12
skin
9
sweat sampling
8
sampling sensing
8
sensing sample
8
volumes reduced
8
reduced μl's
8
μl's nl's
8

Similar Publications

Availability of a suitable tool for carrying out non-invasive measurement of Raman signatures in situ, from biological tissues having low Raman cross section is a clinically unmet need faced with manifold challenges. A Raman probe can prove to be an invaluable component of clinical Raman diagnostic systems. We present development of a Raman probe capable of measuring artefact free Raman spectra of biological tissues in situ.

View Article and Find Full Text PDF

Background: Low-volume hypertonic solutions, such as half-molar lactate (LAC), may be a potential treatment used for fluid resuscitation. This study aimed to evaluate the underlying cardiovascular effects and mechanisms of LAC infusion compared to sodium-matched hypertonic sodium chloride (SAL).

Methods: Eight healthy male participants were randomized in a controlled, single-blinded, crossover study.

View Article and Find Full Text PDF

Background: Postoperative nausea and vomiting (PONV) after orthognathic surgery remains one of the most common side effects despite the use of several medications.

Purpose: The study aimed to compare the frequencies of PONV between a combination of metoclopramide with granisetron and granisetron alone.

Study Design, Setting, Sample: A randomized double-blind clinical trial was conducted in 66 consecutive patients who underwent orthognathic surgery at the Department of Oral and Maxillofacial Surgery at Bezmialem Vakif University.

View Article and Find Full Text PDF

Forest restoration has been a common practice to safeguard water quality and stream health but it is unclear to which extent and pace forest restoration recovers stream ecosystem structure and functions. Also, stream health might be affected by the forest restoration type and the quality of the interventions. Here, we sought to evaluate the recovery of stream habitat and water quality through forest restoration in catchments dominated by pasturelands, and explored the relationship between landscape structure and stream ecosystem recovery.

View Article and Find Full Text PDF

A statistical approach for interplanar spacing metrology at a relative uncertainty below 10 using scanning transmission electron microscopy.

Micron

January 2025

Department of Materials Science and Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel Aviv University, Tel Aviv 6997801, Israel. Electronic address:

Atomic-scale metrology in scanning transmission electron microscopy (STEM) allows to measure distances between individual atomic columns in crystals and is therefore an important aspect of their structural characterization. Furthermore, it allows to locally resolve strain in crystals and to calibrate precisely the pixel size in STEM. We present a method dedicated to the evaluation of interplanar spacing (d-spacing) based on an algorithm including curve fitting of processed high-angle annular dark-field STEM (HAADF STEM) signals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!