Objective: The purpose of this study was to evaluate the effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization.
Methods: A prospective randomized trial was conducted on subjects receiving the standard taping method (group S) compared to a compressive device method (group C) after removal of the cannula in radial artery catheterization. Primary outcomes were the success rate of hemostasis and complication rate after cannula removal. Secondary outcomes were the cost of compression and the level of convenience.
Results: A total of 250 subjects were enrolled in this study. Hemostasis after removal was successful in 122 of 125 (97.6%) subjects in group S and 116 of 125 (92.8%) subjects in group C (P=0.18). Complication rates in group S and group C were 55.2% (69/125) and 48% (60/125), respectively (P=0.35). The cost of compression for group C (approximately 6,740 Korean won) was approximately two times cheaper than for group S (approximately 14,140 Korean won). The level of convenience was significantly higher in group C than in group S (7.4±2.1 vs. 3.7±1.9, p < 0.001).
Conclusion: These findings suggest that hemostasis using a compressive device may be a suitable alternative method to the standard taping method in controlling hemorrhage following radial artery cannulation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052858 | PMC |
http://dx.doi.org/10.15441/ceem.14.018 | DOI Listing |
Sci Rep
December 2024
Department of Vascular Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.
Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.
Polyurethane sponge is frequently selected as a substrate material for constructing flexible compressible sensors due to its excellent resilience and compressibility. However, being highly hydrophilic and flammable, it not only narrows the range of use of the sensor but also poses a great potential threat to human safety. In this paper, a conductive flexible piezoresistive sensor (CHAP-PU) with superhydrophobicity and high flame retardancy was prepared by a simple dip-coating method using A-CNTs/HGM/ADP coatings deposited on the surface of a sponge skeleton and modified with polydimethylsiloxane.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.
Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.
View Article and Find Full Text PDFBMC Oral Health
December 2024
Department of Conservative Dentistry, Faculty of Dentistry, Minia University, Minia, Egypt.
Objectives: To compare the mechanical performance of partially replaced (repaired) intra-coronal restorations to totally replaced ones in root canal-treated teeth.
Methods: Thirty maxillary second premolars were selected according to strict criteria, mounted on moulds, and had mesio-occluso-distal (MOD) cavities prepared. Resin composite restorative material was used to perform the initial restoration, followed by aging procedures using thermo-mechanical cycling fatigue to replicate six months of intraoral aging.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!