Background: Occlusal contact on the implant superstructures is important for successful treatment. The purpose of this study was to investigate the occlusal contact of single implant superstructures at the mandibular first molar immediately after seating from weak to strong clenching.

Methods: Subjects were nine patients who had just been fitted with an implant prosthesis in the mandibular first molar region, with no missing teeth other than in the implant region. First, while masseter muscle activity was monitored, maximum clenching strength (100 % maximum voluntary contraction (MVC)) was determined with an electromyogram. Next, occlusal load and occlusal contact area were measured three times at clenching intensities of 40, 60, 80, and 100 % MVC by the use of pressure-sensitive film for occlusal force diagnostic and Occluzer for occlusal force measurement. Finally, the occlusal contact area was measured once each at 20, 40, and 60 % MVC using a silicone testing material and BiteEye for occlusal contact measurement. A two-way analysis of variance (ANOVA) was used to determine occlusal loading and occlusal area as dependent variables, and clenching strength and presence or absence of implant as between-subject factors. A multiple comparison test was performed using the Bonferroni method.

Results: The occlusal contact area and occlusal load of the implant prosthesis increased with clenching strength, and the increases in occlusal contact area and occlusal load of the implant prosthesis were less than those of the contralateral tooth at high clenching strength. However, significant difference was not observed when compared with both sides of the molar region regardless of clenching strength.

Conclusions: The occlusal contact area of the implant had a tendency to be adjusted smaller than the natural tooth by a dental technician and a dentist. On the other hand, despite the small tissue displaceability of the implant, occlusal load on the implant prosthesis was smaller than on the natural tooth at high clenching strength.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5005633PMC
http://dx.doi.org/10.1186/s40729-015-0016-0DOI Listing

Publication Analysis

Top Keywords

occlusal contact
32
clenching strength
20
contact area
20
occlusal
17
implant prosthesis
16
occlusal load
16
implant superstructures
12
mandibular molar
12
load implant
12
implant
11

Similar Publications

The technical development of implant-supported fixed dental prostheses (iFDP) initially concentrated on the computer-aided manufacturing of prosthetic restorations (CAM). Advances in information technologies have shifted the focus for optimizing digital workflows to AI-based processes for design (CAD). This pre-clinical pilot trial investigated the feasibility of the automatic design of three-unit iFDPs using CAD software (Dental Manger 2021, 3Shape; DentalCAD 3.

View Article and Find Full Text PDF

Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An Study.

J Contemp Dent Pract

September 2024

Department of Preventive and Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.

Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.

Materials And Methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency.

View Article and Find Full Text PDF

Background: Different protocols exist regarding wear time of invisible aligners. There is no study that compared the effect of different protocols. The aim of this study was to assess the effect of Invisalign aligners in four first-premolar extraction treatments in adolescents using three aligner wear protocols, every 7, 10 and 14 days.

View Article and Find Full Text PDF

Aim: Aberrative occlusal contacts were associated with Temporomandibular disorder (TMD), but whether stabilization splints with therapeutic exercises alleviate the symptoms is unclear. Hence, this study aims to compare the short-term efficacy of occlusal splint therapy and the synergistic effect of therapeutic exercise with occlusal splint therapy for 3 weeks in individuals with TMD.

Settings And Design: in-vivo observational pilot study.

View Article and Find Full Text PDF

Occlusion plays a crucial role in the long-term success and functionality of dental restorations. The purpose of this study was to investigate the changes in occlusal contacts upon the cementation of zirconia crowns with different cement spacer settings in computer-aided design and computer-aided manufacturing (CAD-CAM) software (3Shape Dental System version 2.102.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!