Purpose: The purpose of this study was to evaluate and compare the flexural strength and microhardness of provisional restorative materials fabricated utilizing rapid prototyping (RP), Computer Assisted Designing and Computer Assisted Milling (CAD-CAM) and conventional method.
Materials And Methods: Twenty specimens of dimensions 25 mm × 2 mm × 2 mm (ADA-ANSI specification #27) were fabricated each using: (1) Three dimensional (3D) printed light-cured micro-hybrid filled composite by RP resin group, (2) a milled polymethyl methacrylate (CH) using CAD-CAM (CC resin group), and (3) a conventionally fabricated heat activated polymerized CH resin group. Flexural strength and microhardness were measured and values obtained were evaluated.
Results: The measured mean flexural strength values (MegaPascals) were 79.54 (RP resin group), 104.20 (CC resin group), and 95.58 (CH resin group). The measured mean microhardness values (Knoop hardness number) were 32.77 (RP resin group), 25.33 (CC resin group), and 27.36 (CH resin group). The analysis of variance (ANOVA) test shows that there is statistically significant difference in the flexural strength values of the three groups ( < 0.05). According to the pairwise comparison of Tukey's honest significant difference (HSD) test, flexural strength values of CC resin group and CH resin group were higher and statistically significant than those of the RP resin group ( < 0.05). However, there was no significant difference between flexural strength values of CC resin and CH resin group ( = 0.64). The difference in microhardness values of the three groups was statistically significant according to ANOVA as well as the intergroup comparison done using the Tukey's HSD () test ( < 0.05).
Conclusions: CC-based CH had the highest flexural strength whereas RP-based 3D printed and light cured micro-hybrid filled composite had the highest microhardness.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5062140 | PMC |
http://dx.doi.org/10.4103/0972-4052.191288 | DOI Listing |
Clin Exp Dent Res
February 2025
Dental Research Center, Dentistry Research Institue and Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
Objectives: To assess the effect of occlusion and implant number/position on stress distribution in Kennedy Class II implant-assisted removable partial denture (IARPD).
Materials And Methods: IARPDs were designed in six models: with one implant (bone level with a platform of 4 mm and length of 10 mm) at the site of (I) canine, (II) between first and second premolars, (III) first molar, (IV) second molar, or two implants at the sites of (V) canine-first molar, and (VI) canine-second molar. A conventional RPD served as control.
Sci Rep
January 2025
Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, 34 Henri Dunant Road, Pathumwan, Bangkok, 10330, Thailand.
To evaluate the effect of sulfinate salt on the bond performance of a two-step self-etch adhesive to an intracoronally bleached pulpal dentin surface. Intracoronally bleached bovine teeth were treated with or without sulfinate salt (sulfinate agent (SA): Clearfil DC activator) before 2-SEA (Clearfil SE Bond 2) application, while unbleached teeth served as the control (n = 5 teeth). Microtensile bond strength (µTBS) using the bonded surface area of 1 mm at the crosshead speed of 1 mm/min measurements after 24 h storage and thermocycles (TC), degree of conversion (DC) analyses by Raman spectroscopy (n = 3 teeth), ultrastructure of resin-dentin interface (n = 3 teeth), and intracoronally bleached pulp chamber dentin surface (n = 3 teeth) observations by scanning electron microscopy (SEM) were subsequently performed.
View Article and Find Full Text PDFCureus
December 2024
Department of Conservative Dentistry and Endodontics, School of Dental Sciences, Krishna Vishwa Vidyapeeth (Deemed to be University), Karad, IND.
Root canal retreatment (Re-RCT) cases have shortcomings due to the ineffective removal of the root canal filling material, eventually leading to endodontic failure. This study aims to test the comparative efficacy of retreatment files in removing calcium silicate-based sealer and epoxy resin-based sealer. Thirty-two single-rooted teeth were decoronated at 15 mm and bio-mechanical preparation was performed.
View Article and Find Full Text PDFACS Omega
January 2025
School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Water-based acrylic emulsions are a crucial component of water-based ink. Preventing visible cracks in emulsion coating during drying is a great challenge due to the high polarity and high surface tension of water. Herein, we propose that the cracking resistance of the coating can be enhanced through the incorporation of hydrophobic silica nanoparticles.
View Article and Find Full Text PDFACS Omega
January 2025
Instituto de Física de São Carlos, Universidade de São Paulo, São Carlos, SP 13560-970, Brasil.
Direct laser writing (DLW) has been recognized as a unique technique for three-dimensional (3D) prototyping with resolution beyond the diffraction limit. One trend in DLW technologies is the use of polymers, given their favorable mechanical properties and optical quality, rendering them promising for the next generation of nonlinear photonic devices. However, absorptive properties that facilitate DLW processes may also hinder the performance of polymers as all-optical devices.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!