Background: Aortic dissection in pregnancy is relatively rare, but it is often fatal. The estimated incidence of aortic dissection in the general population is 2.9 per 100,000 person-years. Early recognition and treatment of aortic dissections are crucial for survival. Whereas the majority of patients who present with aortic dissection are older than 50 years of age and have a history of hypertension, younger patients with connective tissue disease, bicuspid aortic valves, or a family history of aortic dissection are also at increased risk for developing this condition.

Case Report: We report the successful diagnosis and surgical repair of an acute type A aortic dissection in a 35-year-old woman who presented to the emergency department (ED) at 37 weeks of gestation. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be alert to the possibility of aortic dissection in any pregnant woman who presents to the ED with unexplained chest, abdominal, or back pain, even those without risk factors for aortic dissection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jemermed.2016.09.001DOI Listing

Publication Analysis

Top Keywords

aortic dissection
32
aortic
10
acute type
8
type aortic
8
dissection
8
dissection 37-week
4
37-week pregnant
4
pregnant patient
4
patient unusual
4
unusual clinical
4

Similar Publications

Prognostic Value of D-Dimer in Acute Type A Aortic Dissection and Intramural Hematoma: Observations from the Acute Aortic Syndrome Group of the Registry of Acute Non-Traumatic Chest Pain in China.

J Am Heart Assoc

January 2025

Department of Cardiovascular Surgery, Beijing Anzhen Hospital, Capital Medical University, and The Key Laboratory of Cardiovascular Remodeling-related Diseases, Ministry of Education, and Beijing Institute of Heart Lung and Blood Vessel Disease Beijing China.

Background: Acute type A aortic dissection (AAD) and acute type A intramural hematoma (AIMH) are life-threatening conditions with high mortality rates, and prognostic indicators are critical for guiding urgent treatment decisions. We assessed the prognostic significance of admission D-dimer levels in patients with AAD and AIMH.

Methods And Results: The prospective, multicenter, observational study in China recruited participants from 2013 to 2019.

View Article and Find Full Text PDF

Background And Objective: Patients with thoracic aortic aneurysm and dissection (TAAD) are often asymptomatic but present acutely with life threatening complications that necessitate emergency intervention. Aortic diameter measurement using computed tomography (CT) is considered the gold standard for diagnosis, surgical planning, and monitoring. However, manual measurement can create challenges in clinical workflows due to its time-consuming, labour-intensive nature and susceptibility to human error.

View Article and Find Full Text PDF

Development and Validation of a Diagnostic Model for Stanford Type B Aortic Dissection Based on Proteomic Profiling.

J Inflamm Res

January 2025

Department of Vascular Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, People's Republic of China.

Purpose: Stanford Type B Aortic Dissection (TBAD), a critical aortic disease, has exhibited stable mortality rates over the past decade. However, diagnostic approaches for TBAD during routine health check-ups are currently lacking. This study focused on developing a model to improve the diagnosis in a population.

View Article and Find Full Text PDF

Type B aortic dissection (TBAD) represents a serious medical emergency with up to a 50% associated 5-year mortality caused by thoracic aorta, dissection-associated aneurysmal (DAA) degeneration, and rupture. Unfortunately, conventional size-related diagnostic methods cannot distinguish high-risk DAAs that benefit from surgical intervention from stable DAAs. Our goal is to use DAA stiffness measured with magnetic resonance elastography (MRE) as a biomarker to distinguish high-risk DAAs from stable DAAs.

View Article and Find Full Text PDF

We report a case of mesenteric ischemia after thoracic endovascular aortic repair (TEVAR) for chronic type B aortic dissection performed at a different institution. Computed tomography angiography findings indicated that the previous TEVAR had been deployed distally into the false lumen. To mitigate this, a large fenestration was created between the false lumen and true lumen.

View Article and Find Full Text PDF