Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To analyze the rate of infections and complications after surgeon-performed, largely ultrasound-guided, central venous catheter (CVC) placement in a pediatric population and to identify patients at high risk of complications.
Methods: All children aged between 4 months and 19 years with a percutaneous CVC inserted between January 1, 2000, and July 31, 2013, were included. Patient records were reviewed retrospectively for the occurrence of infection and other complications until CVC removal or the last outpatient clinic visit and compared between patient groups and with the recent literature.
Results: A total of 538 CVCs were placed in 345 patients. Eight patients (1.5%) suffered complications during placement. There were 84 cases of a suspected CVC infection (15.6%). Catheter-related infections with a positive catheter tip culture occurred in 25 cases (4.6%). Older patients (odds ratio [OR] 0.88; 95% confidence interval [CI] 0.78-0.98) or patients with a double-lumen 7 French Bard-Hickman catheter (OR 0.32; 95% CI 0.11-1.00) had a significantly lower risk of infection. Older patients (OR 0.94; 95% CI 0.89-0.99) and patients with beta-thalassemia (OR 0.35; 95% CI 0.17-0.71) also had a significantly lower risk of suspected infection.
Conclusion: In general, infection rates in our series were similar to those in the recent literature. Younger patients seem to be at higher risk for CVC removal because of infection prior to the end of treatment. Patients with beta-thalassemia or receiving a double-lumen 7F Bard-Hickman catheter had a lower risk of infection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/sur.2016.113 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!