A New Strategy for Fast MRI-Based Quantification of the Myelin Water Fraction: Application to Brain Imaging in Infants.

PLoS One

INSERM U992, CEA/DRF/I2BM/Neurospin/UNICOG, Gif-sur-Yvette, France; Université Paris Saclay, Université Paris-Sud, Gif-sur-Yvette, France.

Published: May 2017

The volume fraction of water related to myelin (fmy) is a promising MRI index for in vivo assessment of brain myelination, that can be derived from multi-component analysis of T1 and T2 relaxometry signals. However, existing quantification methods require rather long acquisition and/or post-processing times, making implementation difficult both in research studies on healthy unsedated children and in clinical examinations. The goal of this work was to propose a novel strategy for fmy quantification within acceptable acquisition and post-processing times. Our approach is based on a 3-compartment model (myelin-related water, intra/extra-cellular water and unrestricted water), and uses calibrated values of inherent relaxation times (T1c and T2c) for each compartment c. Calibration was first performed on adult relaxometry datasets (N = 3) acquired with large numbers of inversion times (TI) and echo times (TE), using an original combination of a region contraction approach and a non-negative least-square (NNLS) algorithm. This strategy was compared with voxel-wise fitting, and showed robust estimation of T1c and T2c. The accuracy of fmy calculations depending on multiple factors was investigated using simulated data. In the testing stage, our strategy enabled fast fmy mapping, based on relaxometry datasets acquired with reduced TI and TE numbers (acquisition <6 min), and analyzed with NNLS algorithm (post-processing <5min). In adults (N = 13, mean age 22.4±1.6 years), fmy maps showed variability across white matter regions, in agreement with previous studies. In healthy infants (N = 18, aged 3 to 34 weeks), asynchronous changes in fmy values were demonstrated across bundles, confirming the well-known progression of myelination.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5063462PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0163143PLOS

Publication Analysis

Top Keywords

post-processing times
8
t1c t2c
8
relaxometry datasets
8
datasets acquired
8
water
5
times
5
strategy
4
strategy fast
4
fast mri-based
4
mri-based quantification
4

Similar Publications

Given close relationships between ocular structure and ophthalmic disease, ocular biometry measurements (including axial length, lens thickness, anterior chamber depth, and keratometry values) may be leveraged as features in the prediction of eye diseases. However, ocular biometry measurements are often stored as PDFs rather than as structured data in electronic health records. Thus, time-consuming and laborious manual data entry is required for using biometry data as a disease predictor.

View Article and Find Full Text PDF

Background: Currently, a majority of institution-specific automatic MRI-based contouring algorithms are trained, tested, and validated on one contrast weighting (i.e., T2-weighted), however their actual performance within this contrast weighting (i.

View Article and Find Full Text PDF

Laser-powder bed fusion (PBF-LB) has enabled production of customised skeletal implants that incorporate porous lattices structures to enable bone ingrowth. However, the inherent surface roughness of PBF-LB, characterised by partially adhered particles and undulating sub-topography, remains a barrier to adoption. As such PBF-LB surfaces require several time-consuming post-processing steps, nevertheless, conventional finishing techniques are often limited by geometrical part complexity, making them unsuitable for porous PBF-LB parts.

View Article and Find Full Text PDF

The time-multiplexing super-resolution concept requires post-processing for extracting the super-resolved image. Moreover, to perform the post-processing image restoration, one needs to know the exact high-resolution encoding pattern. Both of these limiting conditions are overcome by the method and experiment reported in this letter.

View Article and Find Full Text PDF

A recent advancement in distributed sensing known as the time-expanded phase-sensitive optical time-domain reflectometry (TE Φ-OTDR) addresses the trade-off between spatial resolution and detection bandwidth, enabling centimeter-scale resolution alongside RF detection bandwidth in the order of MHz. To date, TE Φ-OTDR approaches extract the fiber response from the first Nyquist zone (NZ). In this Letter, we propose a post-processing strategy to enhance the SNR by spectrally averaging different NZs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!