Athlete-tracking devices that include global positioning system (GPS) and microelectrical mechanical system (MEMS) components are now commonplace in sport research and practice. These devices provide large amounts of data that are used to inform decision making on athlete training and performance. However, the data obtained from these devices are often provided without clear explanation of how these metrics are obtained. At present, there is no clear consensus regarding how these data should be handled and reported in a sport context. Therefore, the aim of this review was to examine the factors that affect the data produced by these athlete-tracking devices and to provide guidelines for collecting, processing, and reporting of data. Many factors including device sampling rate, positioning and fitting of devices, satellite signal, and data-filtering methods can affect the measures obtained from GPS and MEMS devices. Therefore researchers are encouraged to report device brand/model, sampling frequency, number of satellites, horizontal dilution of precision, and software/firmware versions in any published research. In addition, details of inclusion/exclusion criteria for data obtained from these devices are also recommended. Considerations for the application of speed zones to evaluate the magnitude and distribution of different locomotor activities recorded by GPS are also presented, alongside recommendations for both industry practice and future research directions. Through a standard approach to data collection and procedure reporting, researchers and practitioners will be able to make more confident comparisons from their data, which will improve the understanding and impact these devices can have on athlete performance.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijspp.2016-0236DOI Listing

Publication Analysis

Top Keywords

devices
9
athlete-tracking devices
8
devices provide
8
data
8
data devices
8
unpacking black
4
black box
4
box applications
4
applications considerations
4
gps
4

Similar Publications

Polarization-Sensitive Solar-Blind Ultraviolet Photodetectors Based on Semipolar (112̅2) AlGaN Film.

ACS Appl Mater Interfaces

January 2025

Research and Development Center for Wide Bandgap Semiconductors, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.

Wide bandgap semiconductor AlGaN alloys have been identified as key materials to fabricate solar-blind ultraviolet photodetectors (SBUV PDs). Herein, a self-driven SBUV polarization-sensitive PD (PSPD) based on semipolar (112̅2)-oriented AlGaN films is reported. Using the flow-rate modulation epitaxy method, the full widths at half maximum (FWHMs) for the obtained (112̅2) AlGaN along [112̅3̅] and [11̅00] rocking curves are 0.

View Article and Find Full Text PDF

Background: This study aimed to assess the contribution of human error to adverse events over 10 years in a single surgical department in South Africa.

Methods: A retrospective database analysis was undertaken to identify all adverse events, which were further assessed to identify which were error-associated.

Results: A total of 14 237 adverse events occurred between December 2012 and January 2023, of which 7 504 (52.

View Article and Find Full Text PDF

Au-In Alloy for Excellent Ohmic Contact in GeSe Devices with Enhanced Photodetector Properties.

ACS Appl Mater Interfaces

January 2025

Key Laboratory of MEMS of Ministry of Education, School of Integrated Circuits, Southeast University, Nanjing 210096, China.

Metal-semiconductor contact plays a significant role in devices such as transistors, photoemitters, and photodetectors. Here, the AuIn alloy contact gives a state-of-the-art low (contact resistance) in GeSe devices. The of GeSe-AuIn is measured to be 25 kΩ μm under channel carrier concentration around = 2.

View Article and Find Full Text PDF

Peri-implant diseases, such as peri-implantitis, affect up to 47% of dental implant recipients, primarily due to biofilm formation. Current decontamination methods vary in efficacy, prompting interest in polymeric nanoparticles (NPs) for their antimicrobial and protein-specific cleaning properties. This study evaluated the efficacy of polymeric nanoparticles (NPs) in decontaminating titanium dental implants by removing proteinaceous pellicle layers and resisting recontamination.

View Article and Find Full Text PDF

Diagonal loading common spatial patterns with Pearson correlation coefficient based feature selection for efficient motor imagery classification.

Comput Methods Biomech Biomed Engin

January 2025

Department of Electronics and Electrical Communications, Faculty of Electronic Engineering, Menoufia University, Menouf, Egypt.

The conversion of a person's intentions into device commands through the use of brain-computer interface (BCI) is a feasible communication method for individuals with nervous system disorders. While common spatial pattern (CSP) is commonly used for feature extraction in BCIs, it has limitations. It is known for its susceptibility to noise and tendency to overfit.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!