Objective: The aim of this study was to measure the clinical crown, anatomical crown, and amount of gingiva covering the enamel of anterior maxillary teeth with soft tissue cone beam computed tomography (ST-CBCT) and thus propose a protocol for the application of this noninvasive method for the planning of esthetic crown lengthening procedures to prevent undesired root exposure.

Materials And Methods: Ten young patients (mean age 22.8 years) requiring esthetic crown lengthening surgeries but not restorative procedures were included in this study. The ST-CBCT images were analyzed with an image editor and analysis software (Pixelmator 3.2), and the clinical crown, anatomical crown, and amount of gingiva covering the enamel were measured.

Results: The mean value of the length of the anatomical crowns of the central incisors, lateral incisors, and canines were 11.06 mm, 9.55 mm, and 9.77 mm, respectively. Thus, the canines were approximately 1.3 mm shorter than the central incisors.

Conclusion: It was shown that ST-CBCT is a useful tool to assess the actual length of the anatomical crown and the amount of gingival tissue that needs to be surgically removed in an esthetic crown lengthening procedure to prevent undesired root exposure. Thus, ST-CBCT is a helpful noninvasive procedure for the planning of esthetic crown lengthening surgeries, making it possible to better predict their final outcome.

Download full-text PDF

Source

Publication Analysis

Top Keywords

esthetic crown
20
crown lengthening
20
planning esthetic
12
anatomical crown
12
crown amount
12
crown
10
soft tissue
8
tissue cone
8
cone beam
8
beam computed
8

Similar Publications

Objectives:  This article compared the accuracy, reproducibility, and gap of crowns resulting from variations in print angulation of three-dimensional (3D)-printed VarseoSmile Crown (VS) and milled resin-ceramic hybrid materials (Cerasmart 270, CS, and Enamic, E).

Materials And Methods:  A total of 60 specimens, consisting of VS printed at four different angulations (30, 45, 60, and 90 degrees), along with CS and E were investigated. External and internal accuracy and reproducibility were measured with the 3D deviation analysis.

View Article and Find Full Text PDF

A comparative evaluation of commercially available short fiber-reinforced composites.

BMC Oral Health

December 2024

Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland.

Background: Short fiber-reinforced composites (SFRCs) are restorative materials for large cavities claimed to effectively resist crack propagation. This study aimed to compare the mechanical properties and physical characteristics of five commercially available SFRCS (Alert, Fibrafill Flow, Fibrafill Dentin, everX Flow, and everX Posterior) against a conventional particulate-filled composite (PFC, Essentia Universal).

Methods: The following characteristics were evaluated in accordance with ISO standards: flexural strength and modulus and fracture toughness.

View Article and Find Full Text PDF

Automatic adjustment of dental crowns using Laplacian mesh editing.

J Mech Behav Biomed Mater

December 2024

Department of Prosthetic Dentistry and Biomedical Materials Science, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. Electronic address:

Currently, the restoration of missing teeth by means of dental implants is a common treatment method in dentistry. Ensuring optimal contact between teeth (occlusion) when designing the occlusal surface of an implant-supported crown is crucial for the patient. Although there are various occlusal concepts and guidelines for achieving optimised occlusion, adapting an occlusal surface is challenging.

View Article and Find Full Text PDF

Amelogenesis imperfecta refers to a group of hereditary diseases that affect dental enamel, often leading to a wide range of clinical manifestations and aesthetic concerns. This case report describes a female patient diagnosed with amelogenesis imperfecta associated with a skeletal open bite. The treatment approach was multidisciplinary.

View Article and Find Full Text PDF

Objective: This study was aimed at assessing the effects of various finish line designs and cement gap thicknesses on the fracture resistance of gradient zirconia crowns.

Methods: Sixty crowns were fabricated on stainless-steel dies with yttria multi-layered (YML) zirconia and categorized into three primary groups according to finish line type (knife-edge, chamfer, and rounded shoulder). Each group was further classified into two subgroups (n = 10) according to cement space thickness (50 or 80 μm).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!