Background: Carotid intima media thickness (CIMT) and the presence of carotid plaque have been used for risk stratification of cardiovascular disease (CVD). To date, however, the association between multi-directional functional properties of carotid artery and CVD has not been fully elucidated. We sought to explore the multi-directional mechanics of the carotid artery in relation to cardiovascular risk.
Methods: Four hundred one patients who underwent carotid ultrasound were enrolled between January 2010 and April 2013. A high risk of CVD was defined as more than 20% of 10-year risk based on the Framingham risk score. Using a speckle-tracking technique, the longitudinal and radial movements were analyzed in the B-mode images. Peak longitudinal and radial displacements, strain and strain rate were also measured. Beta stiffness and elastic modulus index were calculated from the radial measurements.
Results: Of the overall sample, 13% (52) of patients comprised the high-risk group. In multivariate logistic regression, CIMT and elastic modulus index were independently associated with a high-risk of CVD {odds ratio (OR): 1.810 [95% confidence interval (CI) 1.249-2.622] and OR: 1.767 (95% CI: 1.177-2.652); = 0.002, 0.006, respectively}. The combination of CIMT and elastic modulus index correlated with a high-risk of CVD more so than CIMT alone.
Conclusion: The elastic modulus index of the carotid artery might serve as a novel surrogate marker of high-risk CVD. Measurement of the multi-directional mechanics of the carotid artery using the speckle tracking technique has potential for providing further information over conventional B-mode ultrasound for stratification of CVD risk.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5050310 | PMC |
http://dx.doi.org/10.4250/jcu.2016.24.3.215 | DOI Listing |
SICOT J
January 2025
Hospital Henri Mondor, University Paris East (UPEC), Avenue du Marechal de Lattre de Tassigny, 94000 Creteil, France.
Background: Hinge fracture on the lateral part of the tibia (LHF) is a common complication of medial Open Wedge High Tibial Osteotomy (OWHTO). Many factors have been described as risks for these fractures, but no study has compared an osteotome or an oscillating saw to prevent LHF following OWHTO.
Methods: This "propensity-score-matched" (PSM) study was conducted from data obtained in the literature from 1974 to November 2024.
Mater Today Bio
February 2025
Shanxi Medical University School and Hospital of Stomatology, Taiyuan, 030001, Shanxi, China.
Bone defects caused by trauma, infection, or tumors present a major clinical challenge. Titanium (Ti) implants are widely used due to their excellent mechanical properties and biocompatibility; however, their high elastic modulus, low surface bioactivity, and susceptibility to infection hinder osseointegration and increase failure rates. There is an increasing demand for implants that can resist bacterial infection while promoting osseointegration.
View Article and Find Full Text PDFJ Phys Condens Matter
January 2025
Mechanical Engineering, Virginia Tech, 635 Prices Fork Road, Blacksburg, Virginia, 24061-0131, UNITED STATES.
Magnetorheological elastomers (MREs) are soft magnetic composites that achieve tunable changes in stiffness and energy response in the presence of a magnetic field. Rigid particle composite (RC) MREs have been studied for decades for their potential applications to automotive dampers and robotic systems. Recently, magnetic fluid composite (FC) MREs have been developed which utilize magnetic fluids as inclusions to elastomers.
View Article and Find Full Text PDFNatl Sci Rev
February 2025
Department of Orthopaedic Surgery, Children's Hospital of Nanjing Medical University, Nanjing 210004, China.
The escalating prevalence of skeletal muscle disorders highlights the critical need for innovative treatments for severe injuries such as volumetric muscle loss. Traditional treatments, such as autologous transplants, are constrained by limited availability and current scaffolds often fail to meet complex clinical needs. This study introduces a new approach to volumetric muscle loss treatment by using a shape-memory polymer (SMP) based on block copolymers of perfluoropolyether and polycaprolactone diol.
View Article and Find Full Text PDFMater Today Bio
February 2025
Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, Jilin, China.
Titanium alloys are widely used in the manufacture of orthopedic prosthesis given their excellent mechanical properties and biocompatibility. However, the primary drawbacks of traditional titanium alloy prosthesis are their much higher elastic modulus than cancellous bone and poor interfacial adhesion, which lead to poor osseointegration. 3D-printed porous titanium alloys can partly address these issues, but their bio-inertness still requires modifications to adapt to different physiological and pathological microenvironments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!