A decrease in the magnetic resonance (MR) imaging bandwidth can be used to increase the signal-to-noise ratio (S/N) at constant imaging time or to maintain the S/N for reduction of imaging time. The effect of bandwidth reduction from the default value of 16 kHz to 8 kHz was evaluated prospectively in 50 patients referred for MR imaging of the head. On intermediate (2,000/30 [repetition time msec/echo time msec]) and more T2-weighted (2,000/90) studies, there were no definite missed diagnoses and no diagnostically important changes in lesion characteristics when the reduced-bandwidth technique was used to obtain half- or quarter-time studies, excluding differences attributable to unintentional changes in patient position between image acquisitions. Chemical shift misregistration artifacts associated with reduced bandwidth are easily recognized with experience and do not interfere with diagnosis, as the artifacts occur in characteristic locations and diminish in most anatomic locations with increasing echo time. This study suggests the feasibility of reduced-bandwidth techniques in clinical MR imaging of the head at high field strength to achieve an increased S/N, to decrease imaging time, or to obtain images in additional projections.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.172.3.771DOI Listing

Publication Analysis

Top Keywords

imaging head
12
imaging time
12
imaging
6
time
6
reduced-bandwidth imaging
4
head decrease
4
decrease magnetic
4
magnetic resonance
4
resonance imaging
4
imaging bandwidth
4

Similar Publications

Determining the differential diagnosis of small scalp cysts identified on a fetus is difficult. In particular, many physicians have difficulty differentiating small meningoceles from small scalp cysts during the prenatal period. Volume contrast imaging increases contrast between tissues, thereby allowing an enhanced view of target structures.

View Article and Find Full Text PDF

Objective: Carotid body tumors (CBTs) are rare neoplasms of the paraganglia at the carotid bifurcation. While typically benign, CBTs occasionally exhibit malignancy, metastasizing to nearby lymph nodes. Histopathologic analysis alone is insufficient to confirm malignancy, requiring metastases to non-neuroendocrine tissue for a definitive diagnosis.

View Article and Find Full Text PDF

The human body is an intricate system, where diverse and complex signaling among different organs sustains physiological activities. The eye, as a primary organ for information acquisition, not only plays a crucial role in visual perception but also, as increasing evidence suggests, exerts a broad influence on the entire body through complex circuits upon receiving light signals which is called non-image-forming vision. However, the extent and mechanisms of light's impact on the body through the eyes remain insufficiently explored.

View Article and Find Full Text PDF

Introduction: Reports of pseudoaneurysms associated with biliary self-expandable metallic stent (SEMS) placement have been increasing. Recently, cases of hepatic pseudoaneurysm rupture caused by double pigtail plastic stents (DPS) have also been reported. The symptoms of pseudoaneurysms are often non-specific, and many cases are diagnosed only after rupture.

View Article and Find Full Text PDF

Widespread screening is crucial for the early diagnosis and treatment of glaucoma, the leading cause of visual impairment and blindness. The development of portable technologies, such as smartphone-based ophthalmoscopes, able to image the optical nerve head, represents a resource for large-scale glaucoma screening. Indeed, they consist of an optical device attached to a common smartphone, making the overall device cheap and easy to use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!