Is anterior glenoid bone block position reliably assessed by standard radiography? A cadaver study.

Orthop Traumatol Surg Res

Clinique générale d'Annecy, 74000 Annecy, France.

Published: December 2016

Background: Standard radiography with an antero-posterior view and Bernageau's glenoid profile view is the method most widely reported in the literature to assess coracoid bone block position and fusion.

Objective: The aim of this cadaver study was to determine whether the antero-posterior and Bernageau's radiographs provide a reliable and reproducible evaluation of the position of a coracoid bone block and its fixation screws.

Method: An isolated scapula showing no evidence of osteoarthritis or other abnormalities was used. The coracoid process was transferred to the anterior glenoid rim. Fixation was with two slightly diverging malleolar screws, chosen of different sizes for ease of identification. Computed tomography (CT) was performed as the reference imaging technique. The standard radiographs were then obtained, using fluoroscopy to accurately position the scapula for the antero-posterior and Bernageau's views. This position was defined as 0°, and radiographs were taken at angles of 5°, 10°, and 15° in all three planes. All radiographs were taken during a single session to ensure that the distance separating the tube from the scapula remained unchanged. The images were exported to OsiriX for analysis. We measured the angles formed by the screws and the glenoid surface, as well as bone block position and overhang. Finally, we used 1-mm thick disks to evaluate bone-to-bone contact.

Results: No correlations were found between values by CT and by standard radiography (both views) for the screw angles or overhang. A space≤1mm between the neck of the scapula and the bone block was not visible on the standard radiographs in any of the positions.

Conclusion: Standard radiography does not provide an accurate analysis of bone block position or bone-to-bone contact. CT is needed to assess bone block and screw position and bone-to-bone contact.

Level Of Evidence: Level III.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2016.08.005DOI Listing

Publication Analysis

Top Keywords

bone block
28
block position
16
standard radiography
12
anterior glenoid
8
position
8
cadaver study
8
coracoid bone
8
antero-posterior bernageau's
8
standard radiographs
8
position bone-to-bone
8

Similar Publications

Objective: Systematic review of literature on the pre-clinical studies of dental implantation in different models by finding out data about primary stability.

Materials And Methods: PubMed, NCBI, Wiley Online Library, MBPI, Elibrary systems were used for search.

Results: Based on the literature review of the described animal species dogs have the most similar bone structure to humans but their usage is complicated by ethics and law reasons.

View Article and Find Full Text PDF

Objectives: In this study, the spread of methylene blue was compared between an ultrasound-guided Pericapsular Nerve Group (PENG) block and a double injection technique, where the approach towards the inferomedial acetabulum was added to the latter.

Methods: The two techniques were performed in 11 fresh frozen cadavers. The spread was measured after anatomical dissection in which the supplying femoral and obturator nerves were identified.

View Article and Find Full Text PDF

Bone fracture ruptures blood vessels and disrupts the bone marrow, the site of new red blood cell production (erythropoiesis). Current dogma holds that bone fracture causes severe hypoxia at the fracture site, due to vascular rupture, and that this hypoxia must be overcome for regeneration. Here, we show that the early fracture site is not hypoxic, but instead exhibits high oxygen tension (> 55 mmHg, or 8%), similar to the red blood cell reservoir, the spleen.

View Article and Find Full Text PDF

The objective of this mini review is to discuss the role of musculoskeletal ultrasound (MSK US) in identification and treatment of pain generators in cervical spine in patients presenting with cervicogenic headache (CEH). CEH is a secondary headache arising from cervical nociceptive structures emerging from facet joints, intervertebral discs, nerves, muscles, fascia and ligaments. It presents a complex challenge in clinical management.

View Article and Find Full Text PDF

Objective: To evaluate the effectiveness of Sub-periosteal Peri-implant Augmented Layer (SPAL) technique performed with deproteinized bovine bone mineral (DBBM), delivered either as particulate (pDBBM) or block (bDBBM), in correcting a peri implant bone dehiscence (PIBD). Implants showing a thick (≥ 2 mm) peri-implant buccal bone plate (PBBP) at placement were also examined.

Material And Methods: Patients with a PIBD ≥ 1 mm, treated with SPAL with either pDBBM (SPAL) or bDBBM (SPAL), and patients with an implant showing a PBBP ≥ 2 mm at insertion (CONTROL) were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!