A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic accuracy of fetal scalp lactate for intrapartum acidosis compared with scalp pH. | LitMetric

Objective: To determine the diagnostic accuracy of fetal scalp lactate sampling (FSLS) and to establish an optimal cut-off value for intrapartum acidosis compared with fetal scalp pH.

Methods: A 20-month retrospective cohort study was conducted of all neonates delivered in our institution for whom fetal scalp blood sampling (FSBS) was performed, matching their intrapartum gasometry to their cord gasometry at delivery (n=243). The time taken from the performance of scalp blood sampling to arterial umbilical cord gas acquisition was 45 min at most. Five arterial cord gasometry patterns were set for assessing the predictive ability of both techniques. Subsequent obstetric management for a pathological value was analysed considering the use of both techniques.

Results: The optimal cut-off value for FSLS was 4.8 mmol/L: this value has 100% sensitivity and 63% specificity for umbilical arterial cord gas pH≤7.0 and base deficit (BD)≥12 detection, and 100% sensitivity and 64% specificity for umbilical arterial cord gas pH≤7.10 and BD≥12 detection, with a false negative rate of <1.3%, improving fetal scalp pH performance. FSLS showed the best area under the curve (AUC) of 0.86 and 0.84 for both arterial cord gasometry patterns, respectively. Expedite birth following lactate criteria would have been the same as following pH criteria (92 obstetric interventions) with no cases of missed metabolic acidosis. In the cohort, 19.8% of cases were discordant, but no cases of metabolic acidosis were in this group.

Conclusions: FSLS improves the detection of metabolic acidosis via fetal scalp pH with an optimal cut-off value of 4.8 mmol/L. FSLS can be used without increasing obstetrical interventions or missing metabolic acidosis.

Download full-text PDF

Source
http://dx.doi.org/10.1515/jpm-2016-0044DOI Listing

Publication Analysis

Top Keywords

fetal scalp
16
cord gas
12
arterial cord
12
diagnostic accuracy
8
accuracy fetal
8
scalp lactate
8
intrapartum acidosis
8
acidosis compared
8
optimal cut-off
8
scalp blood
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!