Background: The increasing use of conducted electronic weapons (CEW) cause concern regarding its secure application, specially regarding the implications in the cardiovascular system.

Methods: The objective was to determine Spark CEW safety through cardiovascular parameters analysis of healthy volunteers subjected to its use.

Results: Volunteers over 18years without cardiovascular disease or recent use of illegal drugs were submitted, before and after being affected with Spark CEW, to clinical evaluation; blood collection for serum laboratory tests; transthoracic electrocardiography at rest, transthoracic echodopplercardiogram and 24hour Holter.

Results: All 71 patients reported being incapable of any voluntary reaction during the shock of the application time. No arrhythmia or myocardial necrosis was related to the use of non-lethal weapon SPARK. Reported adverse events were self-limited, and mostly mild.

Conclusions: SPARK brand CEW is effective in incapacitating individuals by the shock of the application time, without causing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2016.08.321DOI Listing

Publication Analysis

Top Keywords

spark cew
8
shock application
8
application time
8
spark
5
cardiovascular
4
cardiovascular effects
4
effects spark
4
spark conducted
4
conducted electrical
4
electrical weapon
4

Similar Publications

Background: Conducted electrical weapons (CEWs) are nonlethal weapons used in tactical environments. Tactical EMS (TEMS) operators provide patient care in environments where CEWs are present. CEWs may produce a spark that can be a source of ignition.

View Article and Find Full Text PDF

Gene therapy for severe hemophilia A uses an adeno-associated virus (AAV) vector and liver-specific promoters that depend on healthy hepatocyte function to achieve safe and long-lasting increases in factor VIII (FVIII) activity. Thus, hepatocyte health is an essential aspect of safe and successful gene therapy. Many people living with hemophilia A have current or past chronic hepatitis C virus infection, metabolic dysfunction-associated steatosis or steatohepatitis, or other conditions that may compromise the efficacy and safety of AAV-mediated gene therapy.

View Article and Find Full Text PDF

Background: The increasing use of conducted electronic weapons (CEW) cause concern regarding its secure application, specially regarding the implications in the cardiovascular system.

Methods: The objective was to determine Spark CEW safety through cardiovascular parameters analysis of healthy volunteers subjected to its use.

Results: Volunteers over 18years without cardiovascular disease or recent use of illegal drugs were submitted, before and after being affected with Spark CEW, to clinical evaluation; blood collection for serum laboratory tests; transthoracic electrocardiography at rest, transthoracic echodopplercardiogram and 24hour Holter.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!