Simultaneous analysis of 35 specific antihypertensive adulterants in dietary supplements using LC/MS/MS.

Biomed Chromatogr

Advanced Analysis Team, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong Health Technology Administration Complex, Cheongju-si, Cheongwoungcheongbuk-do, Republic of Korea.

Published: April 2017

A sensitive and specific LC/MS/MS method was developed for the simultaneous analysis of 35 compounds used for treating hypertension as adulterants in dietary supplements. The method was validated for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation, stability and recovery. The limit of detection and limit of quantitation ranged from 0.20 to 20.0 and 0.50 to 60.0 ng/g, respectively. The linearity was good (r  > 0.999), with intra- and interday precision levels of 0.43-7.87% and 0.65-9.95% and the intra- and interday accuracies of 84.36-115.82% and 83.78-118.69%, respectively. The stability (relative standard deviation) was <14.75%. The mean recovery was 80.81-117.86% (relative standard deviation <10.00%). Ninety-seven commercial dietary supplements available in South Korea were analyzed. While none contained detectable amounts of the 35 antihypertensive compounds, the developed LC/MS/MS procedure can be used for routine analysis to monitor illegal adulteration in various forms of dietary supplements.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.3856DOI Listing

Publication Analysis

Top Keywords

simultaneous analysis
8
adulterants dietary
8
dietary supplements
8
limit detection
8
detection limit
8
limit quantitation
8
intra- interday
8
analysis specific
4
specific antihypertensive
4
antihypertensive adulterants
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!