A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In-Vial Temperature Gradient Headspace Single Drop Microextraction Designed by Multiphysics Simulation. | LitMetric

In-Vial Temperature Gradient Headspace Single Drop Microextraction Designed by Multiphysics Simulation.

Anal Chem

Laboratory of Analytical Biochemistry and Bioseparation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology, Shanghai Jiao Tong University, Shanghai, 200240, China.

Published: November 2016

Presented herein is a novel headspace single drop microextraction (HS-SDME) based on temperature gradient (TG) for an on-site preconcentration technique of volatile and semivolatile samples. First, an inner vial cap was designed as a cooling device for acceptor droplet in HS-SDME unit to achieve fast and efficient microextraction. Second, for the first time, an in-vial TG was generated between the donor phase in a sample vial at 80 °C and the acceptor droplet under the inner vial cap containing cooling liquid at -20 °C for a TG-HS-SDME. Third, a simple mathematic model and numerical simulations were developed by using heat transfer in fluids, Navier-Stokes and mass balance equations for conditional optimization, and dynamic illumination of the proposed extraction based on COMSOL Multiphysics. Five chlorophenols (CPs) were selected as model analytes to authenticate the proposed method. The comparisons revealed that the simulative results were in good agreement with the quantitative experiments, verifying the design of TG-HS-SDME via the numerical simulation. Under the optimum conditions, the extraction enrichments were improved from 302- to 388-fold within 2 min only, providing 3.5 to 4 times higher enrichment factors as compared to a typical HS-SDME. The simulation indicated that these improvements in the extraction kinetics could be attributed due to the applied temperature gap between the sample matrix and acceptor droplet within the small volume of headspace. Additionally, the experiments demonstrated a good linearity (0.03-100 μg/L, R > 0.9986), low limit of detection (7-10 ng/L), and fair repeatability (<5.9% RSD, n = 6). All of the simulative and experimental results indicated the robustness, precision, and usefulness of TG-HS-SDME for trace analyses of analytes in a wide variety of environmental, pharmaceutical, food safety, and forensic samples.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.6b02514DOI Listing

Publication Analysis

Top Keywords

acceptor droplet
12
temperature gradient
8
headspace single
8
single drop
8
drop microextraction
8
inner vial
8
vial cap
8
in-vial temperature
4
gradient headspace
4
microextraction designed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!