Background: The efficacy of tranexamic acid (TXA) in reducing blood loss and transfusion requirements in total hip and knee arthroplasty has been well established in small controlled clinical trials and meta-analyses. The purpose of the current study was to determine the risks and benefits of TXA use in routine orthopaedic surgical practice on the basis of data from a large, statewide arthroplasty registry.

Methods: From April 18, 2013, to September 30, 2014, there were 23,236 primary total knee arthroplasty cases and 11,489 primary total hip arthroplasty cases completed and registered in the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI). We evaluated the association between TXA use and hemoglobin drop, transfusion, length of stay (LOS), venous thromboembolism (VTE), readmission, and cardiovascular events by fitting mixed-effects generalized linear and mixed-effects Cox models. We used inverse probability of treatment weighting to enhance causal inference.

Results: For total hip arthroplasty, TXA use was associated with a smaller drop in hemoglobin (mean difference = -0.65 g/dL; 95% confidence interval [CI] = -0.60 to -0.71 g/dL), decreased odds of blood transfusion (odds ratio [OR] = 0.72; 95% CI = 0.60 to 0.86), and decreased readmissions (OR = 0.77; 95% CI = 0.64 to 0.93) compared with no TXA use. There was no effect on VTE (hazard ratio [HR] = 0.91; 95% CI = 0.62 to 1.33), LOS (incident rate ratio [IRR] = 1.00; 95% CI = 0.97 to 1.03), or cardiovascular events (OR = 0.85; 95% CI = 0.47 to 1.52). For total knee arthroplasty, TXA was associated with a smaller drop in hemoglobin (mean difference = -0.68 g/dL; 95% CI = -0.64 to -0.71 g/dL) and one-fourth the odds of blood transfusion (OR = 0.26; 95% CI = 0.21 to 0.31). There was an association with decreased risk of VTE within 90 days after surgery (HR = 0.56; 95% CI = 0.42 to 0.73), slightly decreased LOS (IRR = 0.93; 95% CI = 0.92 to 0.95), and no association with readmissions (OR = 0.90; 95% CI = 0.79 to 1.04) or cardiovascular events (OR = 1.12; 95% CI = 0.74 to 1.71).

Conclusions: In routine orthopaedic surgery practice, TXA use was associated with decreased blood loss and transfusion risk for both total knee and total hip arthroplasty, without evidence of increased risk of complications. TXA use was also associated with reduced risk of readmission among total hip arthroplasty patients and reduced risk of VTE among total knee arthroplasty patients, and did not have an adverse effect on cardiovascular complications in either group.

Level Of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.15.01010DOI Listing

Publication Analysis

Top Keywords

knee arthroplasty
20
total hip
20
total knee
16
hip arthroplasty
16
txa associated
16
cardiovascular events
12
95%
12
arthroplasty
11
total
9
tranexamic acid
8

Similar Publications

Objective: This study aims to elucidate the impact of varying tourniquet application timings on postoperative pain and the bone cement interface following TKA.

Method: Patients who underwent TKA in our department between March 2021 and July 2023 were included in this study. They were randomly assigned to three groups: Group 1 used tourniquets throughout the operation, Group 2 applied tourniquets before the osteotomy, and Group 3 applied tourniquets after completing the osteotomy.

View Article and Find Full Text PDF

Background: Previous clinical studies suggest that preserving the anterior cruciate ligament (ACL) is crucial for stable knee motion and long-term longevity of the reconstructed knee. The ACL damage or loss often occurs in advanced medial osteoarthritis (OA). This study aimed to investigate the correlation between ACL damage and varus deformity progression as a risk factor for ACL tears in knee OA.

View Article and Find Full Text PDF

Background: Arthroplasty registries play a critical role in improving the quality of care and performing post-market surveillance of medical devices. We report the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) findings specific to the Biomet Vanguard XP bicruciate-retaining total knee implant.

Methods: Data were collected from MARCQI's 2019 report (February 15, 2012, through December 31, 2018).

View Article and Find Full Text PDF

Background: Robotic-assisted total knee arthroplasty (RA-TKA) was introduced to provide surgeons with virtual preoperative planning and intraoperative information to achieve the desired surgical goals in an effort to improve patient outcomes. The purpose of this study was to compare clinical outcomes and patient-reported outcome measures following primary TKA using RA-TKA vs manual instrumentation.

Methods: This was a retrospective cohort review study comparing 393 primary RA-TKAs vs 312 manual TKAs at a minimum 2-year follow-up.

View Article and Find Full Text PDF

Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!