Purpose: To compare the three-dimensional (3D) accuracy of conventional direct implant impressions with digital implant impressions from three intraoral scanners, as well as different implant levels-bone level (BL) and tissue level (TL).

Materials And Methods: Two-implant master models were used to simulate a threeunit implant-supported fixed dental prosthesis. Conventional test models were made with direct impression copings and polyether impressions. Scan bodies were hand-tightened onto master models and scanned with the three scanners. This was done for the TL and BL test groups, for a total of eight test groups (n = 5 each). A coordinate measuring machine measured linear distortions (dx, dy, dz), global linear distortion (dR), angular distortions (dθy, dθx), and absolute angular distortions (Absdθy, Absdθx) between the master models, test models, and .stl files of the digital scans.

Results: The mean dR ranged from 35 to 66 μm; mean dθy angular distortions ranged from -0.186 to 0.315 degrees; and mean dθx angular distortions ranged from -0.206 to 0.164 degrees. Two-way analysis of variance showed that the impression type had a significant effect on dx, dz, and Absdθy, and the implant level had a significant effect on dx and Absdθx (P < .05). Among the BL groups, the mean dR of the conventional group was lower than and significantly different from the digital test groups (P = .010), while among the TL groups, there was no statistically significant difference (P = .572).

Conclusion: The 3D accuracy of implant impressions varied according to the impression technique and implant level. For BL test groups, the conventional impression group had significantly lower distortion than the digital impression groups. Among the digital test groups, the TR system had comparable mean linear and absolute angular distortions to the other two systems but exhibited the smallest standard deviations.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.4942DOI Listing

Publication Analysis

Top Keywords

test groups
20
angular distortions
20
implant impressions
16
implant level
12
master models
12
three-dimensional accuracy
8
implant
8
digital implant
8
test models
8
groups
8

Similar Publications

Genomic sequencing in diverse and underserved pediatric populations: parent perspectives on understanding, uncertainty, psychosocial impact, and personal utility of results.

Genet Med

January 2025

Genomics Ethics, and Translational Research Program, RTI International, Research Triangle Park, NC; Department of Translational and Applied Genomics, Kaiser Permanente Center for Health Research, Portland, OR. Electronic address:

Purpose: Limited evidence evaluates parents' perceptions of their child's clinical genomic sequencing (GS) results, particularly among individuals from medically underserved groups. Five Clinical Sequencing Evidence-Generating Research (CSER) consortium studies performed GS in children with suspected genetic conditions with high proportions of individuals from underserved groups to address this evidence gap.

Methods: Parents completed surveys of perceived understanding, personal utility, and test-related distress after GS result disclosure.

View Article and Find Full Text PDF

Purpose: We hypothesized that radiation-induced tubulointerstitial changes in the kidney can be assessed using MRI-based T relaxation time measurements.

Methods: We performed MRI, histology, and serum biochemistry in two mouse models of radiation nephropathy: one involving external beam radiotherapy and the other using internal irradiation with an α-particle-emitting actinium-225 radiolabeled antibody. We compared the mean T values of different renal compartments between control and external beam radiotherapy or α-particle-emitting actinium-225 radiolabeled antibody-treated groups and between the two radiation-treated groups using a Wilcoxon rank-sum test.

View Article and Find Full Text PDF

Background: Polycystic Ovarian Syndrome (PCOS) is an endocrine disorder associated with increased risk of kidney and liver damage. Current treatments have shown contradictory outcomes, and their long-term use causes unwanted side effects. could serve as a complementary medicine to current PCOS treatments.

View Article and Find Full Text PDF

Anti-arthritic potential of crude sulfated polysaccharide from marine macroalgae (Turner) C. Agardh: Regulation of cytokine cascade.

Biomol Concepts

January 2025

Division of Pharmacology, School of Medical and Life Sciences, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, 47500 Selangor Darul Ehsan, Malaysia.

Seaweeds have been utilized as food, fodder, fertilizer, and medicine since ancient times; nevertheless, they have received only a little attention. In the current work, we extracted the sulfated polysaccharide from a marine source and investigated its anti-arthritic potential . The isolated and freeze-dried polysaccharide was tested for acute oral toxicity based on OECD 423.

View Article and Find Full Text PDF

Background: Verbal autopsy (VA) has been a crucial tool in ascertaining population-level cause of death (COD) estimates, specifically in countries where medical certification of COD is relatively limited. The World Health Organization has released an updated instrument (Verbal Autopsy Instrument 2022) that supports electronic data collection methods along with analytical software for assigning COD. This questionnaire encompasses the primary signs and symptoms associated with prevalent diseases across all age groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!