Objectives: Aortic valve preparation with balloon aortic valvuloplasty (BAV) has been previously considered mandatory during transcatheter aortic valve implantation (TAVI) procedures. BAV-inherent risks including stroke, conduction abnormalities, and reduced device profile size established the rationale for safe valve deployment without the need for aggressive valve preparation. We investigate the feasibility and safety of performing Sapien 3 (S3; Edwards Lifesciences) balloon-expandable TAVI with moderate or without predilation (PD).
Methods: We examined consecutive patients with severe aortic stenosis who underwent S3-TAVI at our institution. Overall, 119 patients underwent TAVI without PD and 126 with moderate PD (mean valvuloplasty balloon diameter, 15.3 ± 2.1 mm). TAVI endpoints and adverse events were considered according to the Valve Academic Research Consortium (VARC)-2 definitions.
Results: Device success for the entire cohort was 98.8%. PD rates were similar between groups. Total fluoroscopy time and amount of contrast used were lower in the no PD group (13 min vs 16.2 min [P<.001] and 71.3 mL vs 81 mL [P=.03], respectively). All-cause mortality up to 30 days was 0% (0/119) in the no PD group vs 1.6% (2/126) in the moderate PD group (P=.49). VARC-2 defined complication rates at 30 days including cerebrovascular accident were similar between groups. Overall, there was no significant difference in survival rate between both groups (hazard ratio, 3.6; 95% confidence interval, 0.80-16.2; P=.09).
Conclusions: Balloon-expandable TAVI using the S3 device with moderate or without balloon PD is feasible and safe. Omission of PD in appropriate cases was associated with reduced fluoroscopy time and total contrast used without affecting procedural success.
Download full-text PDF |
Source |
---|
Am J Physiol Heart Circ Physiol
January 2025
Cardiovascular Translational Research. Navarrabiomed (Fundación Miguel Servet), Instituto de Investigación Sanitaria de Navarra (IdiSNA), Hospital Universitario de Navarra (HUN), Universidad Pública de Navarra (UPNA), Pamplona, Spain.
Diabetes mellitus (DM) increases the risk of aortic stenosis (AS) and worsens its pathophysiology in a sex-specific manner. Aldosterone/mineralocorticoid receptor (Aldo/MR) pathway participates in early stages of AS and in other diabetic-related cardiovascular complications. We aim to identify new sex-specific Aldo/MR targets in AS complicated with DM.
View Article and Find Full Text PDFThe authors propose a modified transcatheter aortic valve replacement technique wherein the removal of the guidewire and delivery catheter immediately after the valve implantation helps to not only shorten the procedure but also decrease complications induced by the guidewire and delivery catheter.
View Article and Find Full Text PDFEur J Cardiothorac Surg
January 2025
Division of Cardiovascular Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Objectives: The aim of this study was to determine the indication and optimal timing for performing a hemiarch procedure in patients undergoing valve-sparing root replacement (VSRR).
Methods: We conducted a retrospective study on 986 patients undergoing VSRR at three tertiary care centres. Inclusion criteria were all patients undergoing elective VSRR.
Echocardiography
January 2025
Cardiology Department, Soroka University Medical Center, Beer-Sheba, Israel.
Background: Timing of treatment of aortic stenosis (AS) is of key importance. AS severity is currently determined by transthoracic echocardiography (TTE) with a main focus on mean trans-aortic gradients. However, echocardiography has its limitations.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan.
Background: The long-term valve durability of supra-annular self-expanding valves (SEV) and intra-annular balloon-expandable valves (BEV) in patients with small aortic annuli remains unexplored.
Aims: This study aimed to determine the long-term bioprosthetic valve durability with SEV versus BEV in patients with small aortic annuli.
Methods: This retrospective study included patients with severe aortic stenosis (AS) and an aortic annulus area of 430 mm or less who underwent transcatheter aortic valve replacement using SEV and BEV between October 2009 and December 2022.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!