Effective plots to assess bias and precision in method comparison studies.

Stat Methods Med Res

Institute for Social and Preventive Medicine, University of Lausanne, Lausanne, Switzerland.

Published: June 2018

Bland and Altman's limits of agreement have traditionally been used in clinical research to assess the agreement between different methods of measurement for quantitative variables. However, when the variances of the measurement errors of the two methods are different, Bland and Altman's plot may be misleading; there are settings where the regression line shows an upward or a downward trend but there is no bias or a zero slope and there is a bias. Therefore, the goal of this paper is to clearly illustrate why and when does a bias arise, particularly when heteroscedastic measurement errors are expected, and propose two new plots, the "bias plot" and the "precision plot," to help the investigator visually and clinically appraise the performance of the new method. These plots do not have the above-mentioned defect and still are easy to interpret, in the spirit of Bland and Altman's limits of agreement. To achieve this goal, we rely on the modeling framework recently developed by Nawarathna and Choudhary, which allows the measurement errors to be heteroscedastic and depend on the underlying latent trait. Their estimation procedure, however, is complex and rather daunting to implement. We have, therefore, developed a new estimation procedure, which is much simpler to implement and, yet, performs very well, as illustrated by our simulations. The methodology requires several measurements with the reference standard and possibly only one with the new method for each individual.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0962280216666667DOI Listing

Publication Analysis

Top Keywords

bland altman's
12
measurement errors
12
altman's limits
8
limits agreement
8
estimation procedure
8
effective plots
4
plots assess
4
bias
4
assess bias
4
bias precision
4

Similar Publications

Reproducibility of peak force for isometric and isokinetic multi-joint leg extension exercise.

BMC Sports Sci Med Rehabil

January 2025

Training and Sports Sciences, University of Applied Sciences Wiener Neustadt, Johannes Gutenberg-Straße 3, Wiener Neustadt, 2700, Austria.

Background: Isokinetic dynamometry is a common tool for evaluating muscle function and is used across various disciplines. Technical advancements have shifted focus towards multi-joint exercises such as the leg press, offering insights into practical human movement dynamics. However, previous reproducibility studies have focused predominantly on single-joint exercises, warranting investigations into the reliability of multi-joint exercises.

View Article and Find Full Text PDF

Unobtrusive pulse rate monitoring by continuous video recording, based on remote photoplethysmography (rPPG), might enable early detection of perioperative arrhythmias in general ward patients. However, the accuracy of an rPPG-based machine learning model to monitor the pulse rate during sinus rhythm and arrhythmias is unknown. We conducted a prospective, observational diagnostic study in a cohort with a high prevalence of arrhythmias (patients undergoing elective electrical cardioversion).

View Article and Find Full Text PDF

A Deep Learning Tool for Minimum Joint Space Width Calculation on Anteroposterior Knee Radiographs.

J Arthroplasty

January 2025

Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA. Electronic address:

Background: Minimum joint space width (mJSW) is an important continuous quantitative metric of osteoarthritis progression in the knee. The purpose of this study was to develop an automated measurement algorithm for mJSW in the medial and lateral compartments of the knee that can flexibly handle native knees as well as knees after arthroplasty.

Methods: We developed an end-to-end algorithm consisting of a deep learning segmentation model plus a computer vision algorithm to measure mJSW in the medial and lateral compartments of the knee.

View Article and Find Full Text PDF

Background: Body composition scores allow for quantifying the volume and physical properties of specific tissues. However, their manual calculation is time-consuming and prone to human error. This study aims to develop and validate CompositIA, an automated, open-source pipeline for quantifying body composition scores from thoraco-abdominal computed tomography (CT) scans.

View Article and Find Full Text PDF

Multi-diagnostic chest-worn patch to detect obstructive sleep apnea and cardiac arrhythmias.

J Clin Sleep Med

January 2025

Division of Sleep Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.

Study Objectives: Evaluate the performance of the SANSA device to simultaneously assess obstructive sleep apnea (OSA) and cardiac arrhythmias.

Methods: Participants suspected or known to have OSA underwent polysomnography (PSG) while wearing SANSA. SANSA's algorithm was trained using 86 records and tested on 67 to evaluate training bias.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!