Mechanical strength is an important critical quality attribute for tablets. It is classically measured, in the pharmaceutical field, using the diametral compression test. Nevertheless, due to small contact area between the tablet and the platens, some authors suggested that during the test, the failure could occur in tension away from the center which would invalidate the test and the calculation of the tensile strength. In this study, the flattened disc geometry was used as an alternative to avoid contact problems. The diametral compression on both flattened and standard geometries was first studied using finite element method (FEM) simulation. It was found that, for the flattened geometry, both maximum tensile strain and stress were located at the center of the tablet, which was not the case for the standard geometry. Experimental observations using digital image correlation (DIC) confirmed the numerical results. The experimental tensile strength obtained using both geometries were compared and it was found that the standard geometry always gave lower tensile strength than the flattened geometry. Finally, high-speed video capture of the test made it possible to detect that for the standard geometry the crack initiation was always away from the center of the tablet.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijpharm.2016.09.088 | DOI Listing |
J Conserv Dent Endod
September 2024
Private Practitioner, Chennai, Tamil Nadu, India.
BMC Oral Health
October 2024
Department of Dental Biomaterials, Faculty of Dentistry, Mansoura University, El Gomhouria St, Mansoura, Dakahlia, 35516, Egypt.
Background: Accumulation of biofilm over composite resin restorations is one of the principal causes of recurrent caries. Therefore, this study aimed to develop antibacterial composite resins by crystalline selenium nanoparticles (SeNPs), assessing the antibacterial, mechanical, and physical properties of the composite resin after SeNPs incorporation.
Methods: SeNPs were synthesized via a green method.
Biomedicines
September 2024
Biofunctional Materials and Devices Research Group, National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Khlong Nueng, Khlong Luang, Pathum Thani 12120, Thailand.
Bone grafts are commonly used in orthopedic and dental surgeries to facilitate bone repair and regeneration. A new type of bone graft, polycaprolactone-infiltrated three dimensionally printed hydroxyapatite (3DP HA/PCL), was previously developed by infiltrating polycaprolactone (PCL) into preformed three-dimensional-printed hydroxyapatite (3DP HA) that was fabricated using binder jetting technology combined with a low-temperature phase transformation process. However, when producing small granules, which are often used for bone grafting, issues of granule agglomeration emerged, complicating the application of this method.
View Article and Find Full Text PDFPolymers (Basel)
September 2024
Postgraduate Program in Health Science and Technology-PPGCTS, Dentistry Department, State University of Paraíba, R. Baraúnas, 351, Bodocongó, Campina Grande 58429-500, PB, Brazil.
The development of hydroxyapatite (HAp) and polyether ether ketone (PEEK) biocomposites has been extensively studied for bone repair applications due to the synergistic properties of the involved materials. In this study, we aimed to develop HAp/PEEK biocomposites using high-energy ball milling, with HAp concentrations (20%, 40%, and 60% /) in PEEK, to evaluate their physicochemical, mechanical, cytotoxicity, and antimicrobial properties for potential applications in Tissue Engineering (TE). The biocomposites were characterized by structure, morphology, apparent porosity, diametral compression strength, cytotoxicity, and antimicrobial activity.
View Article and Find Full Text PDFCureus
July 2024
Department of Mechanical and Mechatronics, College of Engineering, Salahaddin University Erbil, Erbil, IRQ.
Background Strength parameters greatly influence the selection of luting agents. This study compared the compressive and diametral tensile strengths (DTS) of three luting cements. Materials and methods Three luting cements, conventional glass ionomer (CGI), resin-modified glass ionomer (RMGI), and resin cement (RC), were tested for compressive strength and DTS.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!