Coronal alignment on the single-limb stance radiograph in posterolateral rotatory instability, osteoarthritis and healthy knees.

Knee

Joint Reconstruction Center, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-gil Bundang-gu, Seongnam-si, Gyeonggi-do 13620, Republic of Korea. Electronic address:

Published: January 2017

Background: We aimed to determine whether coronal alignment measured on the single-limb stance (SLS) radiographs differs from those on the double-limb stance (DLS) images. We also investigated whether the size of such differences was affected by the knee pathology, lower limb alignment, and geometry of the tibia or femur.

Methods: We measured coronal alignment with mechanical tibiofemoral angle (MTFA) on the DLS and SLS radiographs in patients with posterolateral rotatory instability (PLRI, 30 knees), osteoarthritis (OA) with varus deformity who were scheduled for high tibial osteotomy (HTO) (60 knees), and in normal control (60 knees). The measurements on the SLS radiographs were compared with those on DLS images and the size of the differences were compared between the three groups. The correlation between the radiograph-related differences of coronal alignment and the limb alignment or geometry of tibia/femur was investigated. In the OA group, the size of the radiograph-related differences before HTO were compared with those after surgery.

Results: The coronal alignment on the SLS radiographs indicated varus accentuation compared to those on the DLS radiographs in the PLRI and OA groups (1.6 and 2.4°, respectively), while it was negligible in the normal group. Greater varus inclination of the tibial plateau was related to greater varus accentuation (r=0.249). The HTO decreased the extent of varus accentuation in the OA group (reduction of varus accentuation=1.5°).

Conclusions: Coronal alignment on the SLS radiograph is different from static alignment measured on the DLS radiograph, which may reflect dynamic alignment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2016.09.003DOI Listing

Publication Analysis

Top Keywords

coronal alignment
24
sls radiographs
16
varus accentuation
12
alignment
9
single-limb stance
8
posterolateral rotatory
8
rotatory instability
8
alignment measured
8
dls images
8
size differences
8

Similar Publications

Background: Hallux valgus (HV) is a complex, multiplanar deformity. In this study, we examined the interrelationships between various components of this deformity using weightbearing computed tomography (WBCT). We hypothesized that the severity of traditional axial plane deformities would correlate with malpositioning of the metatarsosesamoid complex, first-ray coronal rotational deformity, and malalignment of the hindfoot and midfoot.

View Article and Find Full Text PDF

: Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses preoperative three-dimensional imaging to create cutting blocks tailored to patient anatomy. However, there is debate regarding the additional benefits of PSI in terms of improved alignment or functional outcomes compared to using conventional instruments. Although PSI design has undergone continuous development, the improvements have not been incorporated.

View Article and Find Full Text PDF

Purpose: Currently, no gold standard exists for 3D analysis of virtually planned surgery accuracy postoperatively. The aim of this study was to present a new, validated and standardised methodology for 3D postoperative assessment of surgical accuracy in patients undergoing 3D virtually planned and guided corrective osteotomies.

Methods: All patients who underwent 3D planned corrective osteotomy in 2021-2022 at our center with a postoperative CT were included.

View Article and Find Full Text PDF

A new 3D full-body scanner analyzing the sagittal and coronal balance of the adult spine: a preliminary prospective observational study.

Acta Neurochir (Wien)

January 2025

Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.

Background: The degenerative spondylosis can cause the difficulty in maintaining sagittal and coronal alignment of spine, and X-ray parameters are the gold standard to analyze the malalignment. This study aimed to develop a new 3D full body scanner to analyze the spinal balance and compare it to X-ray parameters.

Methods: Ninety-seven adult participants who suffer degenerative spondylosis underwent 3D full body scanning, whole spine X-rays, clinical questionnaires and body composition analyses.

View Article and Find Full Text PDF

Introduction: The use of robots for arthroplasty is gaining momentum in recent times to provide accuracy in bony cuts and alignment. We aimed to study the efficacy of coronal plane correction with a new robotic system (VELYS™ Robotic-Assisted Surgery) and also the effect of the learning curve of robot-assisted total knee arthroplasty (RATKA) on outcomes. We hypothesize that the benefits of RATKA are not limited to only surgeons having specific training in robotic knee replacement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!