Nitrogen-assisted nanoelectrospray emitter (NANE) was developed to achieve accurate mass-to-charge ratio (m/z) measurements with a single monolithic nozzle. Deposition patterns of generated electrosprays from NANE confirmed their wrapped configurations. Additionally, the intensity of the sample ion and its ratio relative to a reference ion was inclined to focus on the central region of the spray; this trend further supported the existence of wrapped configurations. Further, the proposed NANE was fabricated from poly-(dimethylsiloxane) (PDMS) with octadecyltrichlorosilane modification to restrain the dissolution of PDMS monomers. Assist nitrogen flows were introduced to improve the ionization of reference ions. Moreover, the NANE could regulate the distribution of reference ions by microfluidic three dimensional hydrodynamic focusing. By regulating the distribution of reference ions, the ionization depression was reduced to some degree, and an improved sensitivity was accomplished compared with the mixing of sample and reference solutions. Achieved relative errors of m/z were between 0.2-4.5ppm and 5.2-9.2ppm for ten organic molecules and four biological macromolecules, respectively. Acceptable linear ranges were obtained in quantifications for rhodamine B and emamectin benzoate. Finally, the NANE was compatible with broad infusion rates (from 50nLmin to 15μLmin) and solutions of different compositions (from 100% methanol to 100% water). Considering the comprehensive application of PDMS in microfluidics, the proposed NANE could be used as a compact and monolithic interface to achieve accurate m/z measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2016.09.065 | DOI Listing |
Sci Bull (Beijing)
December 2024
Laboratory of Nuclear Energy Chemistry, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China. Electronic address:
Tailored design of organic linkers or metal nodes can introduce desirable functionalities into metal-organic cages (MOCs), significantly expanding their potential applications. In this study, we present a viable approach for engineering acyl-type metal nodes to create interior oxygen-rich sites within MOCs, enabling specific recognition of metal ions, including radioactive contaminants, while maintaining the structural integrity of the MOCs. A novel MOC featuring a uranyl-sealed calix[4]resorcinarene (C[4]R)-based multisite cavity, referred to as UOC, is synthesized as a prototype.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Department of Chemistry, National Chung Hsing University, Taichung City, 402202, Taiwan, ROC. Electronic address:
Background: To integrate valves, manifolds, and solid-phase extraction (SPE) columns into a compact device is technically difficult. Four-dimensional printing (4DP) technologies, employing stimuli-responsive materials in three-dimensional printing (3DP), are revolutionizing the fabrication, functionality, and applicability of stimuli-responsive analytical devices that can show time-dependent shape programming to enable more complex geometric designs and functions. However, 4D-printed stimuli-responsive actuators and valves utilized to control flowing streams in SPE applications remain rare.
View Article and Find Full Text PDFBMJ Open
January 2025
Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, Tyne and Wear, UK
Introduction: Persistent throat symptoms (PTS) are indicators for over 60 000 new patient referrals to NHS secondary care annually. PTS have been attributed to manifestation of gastro-oesophageal reflux disease (GORD) with the hypothesis that gastric refluxate damages and irritates the mucosa of the upper aerodigestive tract. Symptoms of PTS and GORD are commonly treated with proton pump inhibitors (PPIs) or alginates are often, incorrectly, advocated.
View Article and Find Full Text PDFChem Sci
December 2024
VASP Software GmbH Berggasse 21 A-1090 Vienna Austria.
Constructing a self-consistent first-principles framework that accurately predicts the properties of electron transfer reactions through finite-temperature molecular dynamics simulations is a dream of theoretical electrochemists and physical chemists. Yet, predicting even the absolute standard hydrogen electrode potential, the most fundamental reference for electrode potentials, proves to be extremely challenging. Here, we show that a hybrid functional incorporating 25% exact exchange enables quantitative predictions when statistically accurate phase-space sampling is achieved thermodynamic integrations and thermodynamic perturbation theory calculations, utilizing machine-learned force fields and Δ-machine learning models.
View Article and Find Full Text PDFBraz Oral Res
January 2025
Universidade Federal da Paraíba - UFPB, Health Science Center Department of Clinical and Community Dentistry, João Pessoa, PB, Brazil.
This study aimed to evaluate the effectiveness of bioactive toothpastes in remineralizing eroded enamel surfaces in vitro. Bovine enamel blocks (n = 48) were obtained and classified into untreated, demineralized, and treated areas. Specimens were randomly classified into six groups (n = 8 each): fluoride-free toothpaste (NCT), Colgate Total 12 (PCT), Sensodyne Repair and Protect (SRP), Sensodyne Pronamel (SPE), Regenerador + Sensitive (RGS), and RGS/calcium booster (RCB).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!