Introduction And Objectives: Left-sided native valve infective endocarditis (LNVIE) epidemiology has been modified as a result of the increase in average age. The aim of our study is to analyze the influence of age and the presence of predisposing heart disease in the prognosis of these patients.

Methods: We analyzed a series of 257 cases of LNVIE depending on their age (greater than or equal to 70 years old), both in the overall series and in the subgroup of patients without predisposing heart disease.

Results: Mean age was 54.6 (18.6) years. There was an increase in the percentage of cases of older patients between 1987-2000 and 2001-2014 (9.8 vs. 34.8%, P<.001). These patients present higher prevalence of degenerative valves (50 vs. 22.8%) or not predisposing heart disease (50 vs. 39.9%), P<.001, health-care associated episodes (41.8 vs. 23.6%, P=.016), lower rate of surgery (43.7 vs. 63.8%, P=.005) and higher in-hospital mortality (39.1 vs. 20.7%, P=.003), with no differences in comorbidities. Older patients who did not have predisposing heart disease also suffered higher in-hospital mortality (47 vs. 22%, P=.01). Age greater than or equal to 70 years old is an independent predictor of mortality in patients with LNVIE (OR 2.53, 95% CI 1.24-5.15, P=.011), as in those without previous heart disease (OR 3.98, 95% CI 1.49-10.62, P=.006).

Conclusions: Patients of age greater than or equal to 70 years old and who suffer an LNVIE are becoming more frequent and have a worse prognosis with a lower rate of surgery and higher rates of in-hospital mortality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medcli.2016.07.017DOI Listing

Publication Analysis

Top Keywords

native valve
8
valve infective
8
infective endocarditis
8
influence age
8
age presence
8
predisposing heart
8
age
5
[left-sided native
4
endocarditis influence
4
presence underlying
4

Similar Publications

Background: Ventricular tachycardia (VT) substrate characteristics before transcatheter pulmonary valve replacement (TPVR) in repaired tetralogy of Fallot (rTOF) are unknown.

Objectives: In this study, the authors sought to evaluate substrates for sustained monomorphic VT before TPVR in rTOF.

Methods: Retrospective (2017 to 2021) and prospective (commencing 2021) rTOF patients with native right ventricular outflow tract referred for electrophysiology study (EPS) before TPVR were included.

View Article and Find Full Text PDF

Background: Valvular heart disease (VHD) is a major focus of cardiovascular medicine, but limited data are available for racial and ethnic minorities. The aim was to assess the burden and clinical correlates of VHD in a highly diverse area of the United States.

Methods And Results: Individuals with echocardiographic diagnosis of native VHD between January 2010 and December 2019 at a quaternary care health system of the Bronx (New York, USA) were included.

View Article and Find Full Text PDF

Native Leaflet Calcification: A Culprit for TAVR Degeneration?

JACC Cardiovasc Interv

January 2025

Department of Cardiology, Shaare Zedek Medical Centre, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel. Electronic address:

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!