Purpose: To investigate monitoring slope-based features of the optic nerve head (ONH) cup as open-angle glaucoma (OAG) occurs.

Method: A dataset of 46 retrospective OCT cases was acquired from the SPECTRALIS Heidelberg Engineering OCT device. A set of five parameters, which are based on the ONH cup-incline, are measured on the OAG and normal subjects in the dataset. Then, three new ONH cup-shape indices were deduced. The ONH cup-incline parameters and ONH cup-shape indices are analyzed to estimate their clinical value.

Results: The statistical difference between measurements on normal and glaucoma eyes was remarkably significant for all of the analyzed parameters and indices (p value < 0.001).

Conclusions: The geometric shape of the ONH cup can be transferred to numerical parameters and indices. The proposed ONH cup-incline parameters and ONH cup-shape indices have shown suggestive clinical value to identify the development of OAG. As OAG appears, the top ONH cup-incline parameters decrease while the bottom ONH cup-incline parameters increase. The ONH cup-shape indices suggest capability to discriminate OAG from normal eyes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10792-016-0362-9DOI Listing

Publication Analysis

Top Keywords

onh cup-incline
20
onh cup-shape
16
cup-shape indices
16
cup-incline parameters
16
onh
11
optic nerve
8
nerve head
8
parameters
8
open-angle glaucoma
8
onh cup
8

Similar Publications

Purpose: To investigate monitoring slope-based features of the optic nerve head (ONH) cup as open-angle glaucoma (OAG) occurs.

Method: A dataset of 46 retrospective OCT cases was acquired from the SPECTRALIS Heidelberg Engineering OCT device. A set of five parameters, which are based on the ONH cup-incline, are measured on the OAG and normal subjects in the dataset.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!