Aim: To evaluate the efficacy of toric intraocular lens markers-assisted implantation of the scleral-fixated intraocular lens (SFIOL).
Methods: From October 2010 to December 2013, all patients who had undergone secondary SFIOL implantation were assigned to group 1 and 2, in group 1 SFIOL was performed with the assist of radial keratotomy (RK)-marker, and in group 2 SFIOL was performed with the assisted of toric intraocular lens markers (T-and axis markers). Patients' demographic data and information on baseline preoperative visual acuity, indication for surgery and latest postoperative visual acuity were collected and analyzed. The haptic and optic positions were determined by ultrasound biomicroscopy. The optic tilt angle and decentration distance were measured.
Results: The study evaluated 43 eyes of 43 patients ranging in age from 3 to 66y. Group 1 comprised 24 eyes (24 patients) and group 2, 19 eyes (19 patients). Uncorrected reoperative acuity was improved on all the eyes postoperatively. The improved postoperative acuity was significantly more in group 2 than that in group 1 (1.11±0.38 vs 0.82±0.45 logMAR; F=4.85, P=0.03). Ultrasonic biomicrograph examination showed that the rate of haptic asymmetry was significantly higher in group 1 (42%, 10/24) than that in group 2 (11%; 2/19) (Chi square=3.68, P=0.04). The mean tilted degree in group 1 was significantly higher than that in group 2 (P=0.04). Mean decentration distance in group 1 was greater than that in group 2 (P=0.03).
Conclusion: During SFIOL the toric markers help the surgeon identify the placement of fixation more precisely than that with the use of RK marker.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5028663 | PMC |
http://dx.doi.org/10.18240/ijo.2016.09.09 | DOI Listing |
Eur J Ophthalmol
January 2025
Ophthalmology Department, ULS São José, Lisboa, Portugal.
Purpose: To compare changes in angle morphology, anterior chamber depth (ACD) and refractive prediction error (PE) after phacoemulsification between pseudoexfoliative (PEX) and non-PEX eyes.
Methods: Prospective case-control study of eyes submitted to cataract surgery. Biometric data and angle parameters - Anterior Chamber Angle (ACA), Angle Opening Distance (AOD), Scleral Spur Angles (SSA) and Trabecular Iris Space Area (TISA) - were measured preoperatively and 1-month postoperatively through swept-source anterior segment optical coherence tomography.
BMC Ophthalmol
January 2025
Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
Purpose: Proliferative vitreoretinopathy (PVR) is a complication of retinal detachment which requires multiple vitreoretinal surgical interventions and frequent use of oil endotamponade. In this study, we conducted an in-depth analysis of complications associated with the use of heavy silicone oil in the management of inferior PVR.
Methods: A retrospective cohort study of 20 eyes that underwent vitrectomy for inferior PVR with use of heavy silicone oil (Densiron 68) between March 2021 and October 2022 at Oxford Eye Hospital.
Purpose: The light adjustable lens (LAL) (RxSight, Aliso Viejo, CA) is a premium intraocular lens that allows for correction of residual refractive error and astigmatism following implantation. Herein, we describe the surgical approach and evaluate the visual outcomes of patients following scleral fixation of the LAL.
Methods: Retrospective, single-surgeon surgical case series of 3 patients (3 eyes) with intraocular lens complications, who underwent combined pars plana vitrectomy and sutureless needle assisted intrascleral haptic fixation of the LAL between April 2022, to August 2023.
Retina
January 2025
Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai 200031, People's Republic of China.
Purpose: To describe a simplified technique for correcting intraocular lens (IOL) decentration during scleral-sutured IOL fixation surgery.
Methods: During surgery, Purkinje images were utilized to assess IOL positioning. A straightforward IOL decentration adjustment technique was employed when necessary.
J Cataract Refract Surg
January 2025
Great Lakes Eye Care, Saint Joseph, MI, USA.
Purpose: To investigate the impact of the distance from the most-anterior surface of the optic to the principal object plane (POP) and from the foremost haptic to the principal object plane (H-POP) on the intraocular lens (IOL) power calculation.
Setting: A tertiary hospital.
Design: Optical simulation and retrospective cross-sectional study.