Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The purpose of this study is to coevaluate resident technical errors and decision-making capabilities during placement of a subclavian central venous catheter (CVC). We hypothesize that there would be significant correlations between scenario-based decision-making skills and technical proficiency in central line insertion. We also predict residents would face problems in anticipating common difficulties and generating solutions associated with line placement.
Design: Participants were asked to insert a subclavian central line on a simulator. After completion, residents were presented with a real-life patient photograph depicting CVC placement and asked to anticipate difficulties and generate solutions. Error rates were analyzed using chi-square tests and a 5% expected error rate. Correlations were sought by comparing technical errors and scenario-based decision-making skills.
Setting: This study was performed at 7 tertiary care centers.
Participants: Study participants (N = 46) largely consisted of first-year research residents who could be followed longitudinally. Second-year research and clinical residents were not excluded.
Results: In total, 6 checklist errors were committed more often than anticipated. Residents committed an average of 1.9 errors, significantly more than the 1 error, at most, per person expected (t(44) = 3.82, p < 0.001). The most common error was performance of the procedure steps in the wrong order (28.5%, p < 0.001). Some of the residents (24%) had no errors, 30% committed 1 error, and 46 % committed more than 1 error. The number of technical errors committed negatively correlated with the total number of commonly identified difficulties and generated solutions (r (33) = -0.429, p = 0.021, r (33) = -0.383, p = 0.044, respectively).
Conclusions: Almost half of the surgical residents committed multiple errors while performing subclavian CVC placement. The correlation between technical errors and decision-making skills suggests a critical need to train residents in both technique and error management.