In dual chamber pacing, an improvement of exercise capacity is expected when the atrial refractory period is shortened, because the 2/1 point is increased. This objective can be achieved by greatly reducing atrioventricular delay (AVD) on exercise. Are such variations (up to 100-120 ms) detrimental from a haemodynamic standpoint? This study was performed to analyse this particular aspect of DDD pacing. Three DDD pacing modes, differing by their AVDs (fixed 200 ms AVD, fixed 150 ms AVD, and rate-adapted AVD) were tested in random order, with a haemodynamic protocol including ten patients with chronic atrio-ventricular (A-V) block. For the rate-adapted AVD pacing mode, AVD was reduced by 20 ms every 10 beats min-1 increment (from 220 ms at 90 beats min-1 to 100 ms at 150 beats min-1). Pacing rate was increased from 90 to 150 beats min-1 by increments of 10 beats min-1 every 5 min. Cardiac performance was significantly improved with the rate-adapted AVD above the two fixed AVDs, despite a large AVD variation. When AVD was rate adapted, cardiac index, stroke volume index and left ventricular systolic work index were generally higher and pulmonary capillary wedge pressure, pulmonary arterial pressure and systemic vascular resistances were generally lower, especially at 120, 130 and 140 beats min-1. Comparing the two fixed AVDs, 200 AVD improved cardiac function more at lower heart rates, whereas 150 AVD improved cardiac function more at higher heart rates. Despite its limitations, this study demonstrates that the potential benefits of reducing AVD with increasing heart rates should be twofold in dual chamber pacing: (a) haemodynamic, optimizing cardiac performance on exercise for all heart rates, especially in cases of organic heart disease; (b) electrophysiologic, permitting a sufficiently rapid maximal tracking rate in cases with long post-ventricular atrial refractory periods, allowing a satisfactory level of exercise.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/oxfordjournals.eurheartj.a059541 | DOI Listing |
Front Physiol
January 2025
Atmosphere and Ocean Research Institute, The University of Tokyo, Kashiwa, Japan.
Clin Kidney J
January 2025
College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Background: Resting heart rate is a potent predictor of various renal outcomes. However, the decline rate of renal function in ischemic stroke patients is not well defined. We tested the association of heart rate with estimated eGFR decline and the composite renal outcomes in patients with recent ischemic stroke.
View Article and Find Full Text PDFMed Sci Sports Exerc
January 2025
FAME Laboratory, Department of Physical Education and Sport Science, University of Thessaly, GREECE.
Purpose: Exercise-induced heat acclimation can mitigate age-related reductions in heat-loss capacity, though performing repeated bouts of strenuous exercise in the heat may be untenable for many older adults. While short-term passive heat acclimation (e.g.
View Article and Find Full Text PDFSports Med Open
January 2025
Department of Health Promotion, Faculty of Medical and Health Sciences, School of Public Health, Tel-Aviv University, Tel-Aviv, Israel.
Background: Studies on rest durations during high-intensity interval training (HIIT) often compare fixed and self-selected (SS) rest allocation approaches. Frequently, the rest duration under SS conditions is unlimited, leading to inconsistent total rest durations compared to fixed rest conditions. To address this limitation, we recently compared fixed and SS rest conditions during cycling HIIT sessions, while keeping the total rest duration equivalent.
View Article and Find Full Text PDFInt J Sports Physiol Perform
January 2025
Department of Sport, Exercise and Health, Faculty of Medicine, University of Basel, Basel, Switzerland.
To define training zones, ventilatory thresholds (VTs) are commonly established by cardiopulmonary gas-exchange analysis during incremental exercise tests. Portable near-infrared spectroscopy (NIRS) devices have emerged as a potential tool for detecting these thresholds by monitoring muscle oxygenation. This study evaluated the accuracy of NIRS measurements to determine VTs or critical power (CP) based on muscle oxygen saturation and assesses the device's consistency across 2 constant-load tests.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!