[THE RAPID TEST METHOD OF IDENTIFICATION OF THE TYPE OF GROWTH OF THE JAW BONE ON THE ORTHOPANTOMOGRAM].

Georgian Med News

Higher State Educational Institution of Ukraine "Ukrainian Medical Stomatological Academy", Department of Postgraduate Education orthodontist, Poltava, Ukraine.

Published: July 2016

The roentgenological methods of research take the lead in the diacrisis of dentofacial anomalies, they are of the utmost importance as for the identification of the jaws' growth character, so too for the generation of the treatment planning and of the expected response to the treatment. The type of the jaw growth is identified by the means of a basal angle on the teleroentgenography (TRG). The objective of the research was to develop a rapid test method of identification of the type of growth by means of a basal angle on the orthopantomogram (OPTG). The comparison of 0,05) during the comparison of angles' indexes on the TRG and OPTG. The proposed rapid test method allows to identify the type of growth of the mandibular bones by the means of basal angle

Download full-text PDF

Source

Publication Analysis

Top Keywords

rapid test
8
test method
8
method identification
8
identification type
8
type growth
8
basal angle
8
[the rapid
4
growth
4
growth jaw
4
jaw bone
4

Similar Publications

A Quantitative First Passage Time Model for Tubular Microfluidic Immunoassays.

ACS Sens

January 2025

Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.

Solid-phase immunosorbent reactions, such as ELISA, are widely used for detecting, identifying, and quantifying protein markers. However, traditional centimeter scale well-based immunoreactors suffer from low surface-to-volume (S/V) ratios, leading to large sample consumption and a long assay time. Microfluidic technologies, particularly tubular microfluidic immunoreactors, have emerged as promising alternatives due to their high S/V ratios.

View Article and Find Full Text PDF

The ionizable lipid component of lipid nanoparticle (LNP) formulations is essential for mRNA delivery by facilitating endosomal escape. Conventionally, these lipids are synthesized through complex, multistep chemical processes that are both time-consuming and require significant engineering. Furthermore, the development of new ionizable lipids is hindered by a limited understanding of the structure-activity relationships essential for effective mRNA delivery.

View Article and Find Full Text PDF

In this paper, we present a new computational framework for the simulation of airway resistance, the fraction of exhaled nitric oxide, and the diffusion capacity for nitric oxide in healthy and unhealthy lungs. Our approach is firstly based on a realistic representation of the geometry of healthy lungs as a function of body mass, which compares well with data from the literature, particularly in terms of lung volume and alveolar surface area. The original way in which this geometry is created, including an individual definition of the airways in the first seven generations of the lungs, makes it possible to consider the heterogeneous nature of the lungs in terms of perfusion and ventilation.

View Article and Find Full Text PDF

Non-targeted analysis (NTA) using high-resolution mass spectrometry without defined chemical targets has the potential to expand and improve chemical monitoring in many fields. Despite rapid advancements within the research community, NTA methods and data remain underutilized by many potential beneficiaries. To better understand barriers toward widespread adoption, the Best Practices for Non-Targeted Analysis (BP4NTA) working group conducted focus group meetings and follow-up surveys with scientists (n = 61) from various sectors (e.

View Article and Find Full Text PDF

A review of state-of-the-art resolution improvement techniques in SPECT imaging.

EJNMMI Phys

January 2025

Department of Nuclear Medicine, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, 230001, Anhui, China.

Single photon emission computed tomography (SPECT), a technique capable of capturing functional and molecular information, has been widely adopted in theranostics applications across various fields, including cardiology, neurology, and oncology. The spatial resolution of SPECT imaging is relatively poor, which poses a significant limitation, especially the visualization of small lesions. The main factors affecting the limited spatial resolution of SPECT include projection sampling techniques, hardware and software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!