Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of the present study was to determine the distribution of lung blood in a modified bilateral Glenn procedure designed in our institute with lung perfusion scintigraphy. Sixteen consecutive patients who underwent modified bilateral Glenn operation from 2011 to 2014 were enrolled in the study. The control group consisted of 7 patients who underwent bidirectional Glenn shunt. Radionuclide lung perfusion scintigraphy was performed using Tc-99m-macro aggregated albumin (MAA) in all patients. For the patients in modified bilateral Glenn group, the time at which the radioactivity accumulation peaked did not differ significantly between the right and left lung field (t = 0.608, P = 0.554). The incidence of perfusion abnormality in each lung lobe also did not differ significantly (P = 0.426 by Fisher exact test). The radioactive counts were higher in the right lung than in the left lung, but the difference was not statistically significant (t = 1.502, P = 0.157). Radioactive perfusion in the lower lung field was significantly greater than that in the upper field (t = 4.368, P < 0.001). Compared with that in the bidirectional Glenn group, the ratio of radioactivity in the right lung to that in left lung was significantly lower in the modified bilateral Glenn group (t = 3.686, P = 0.002). Lung perfusion scintigraphy confirmed the benefit of the modified bilateral Glenn shunt with regard to more balanced blood perfusion in both lungs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5044912 | PMC |
http://dx.doi.org/10.1097/MD.0000000000004920 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!