Objectives: This study sought to investigate the impact of transcatheter intervention on left ventricular function and aortic hemodynamics in patients with mild coarctation of the aorta (COA).
Background: The optimal method and timing of transcatheter intervention for COA remains unclear, especially when the severity of COA is mild (peak-to-peak transcoarctation pressure gradient <20 mm Hg). Debate rages regarding the risk/benefit ratio of intervention versus long-term effects of persistent minimal gradient in this heterogeneous population with differing blood pressures, ventricular function, and peripheral perfusion.
Methods: We developed a unique computational fluid dynamics and lumped parameter modeling framework based on patient-specific hemodynamic input parameters and validated it against patient-specific clinical outcomes (before and after intervention). We used clinically measured hemodynamic metrics and imaging of the aorta and the left ventricle in 34 patients with mild COA to make these correlations.
Results: Despite dramatic reduction in the transcoarctation pressure gradient (catheter and Doppler echocardiography pressure gradients reduced by 75% and 47.3%, respectively), there was only modest effect on aortic flow and no significant impact on aortic shear stress (the maximum time-averaged wall shear stress in descending aorta was reduced 5.1%). In no patient did transcatheter intervention improve left ventricular function (e.g., stroke work and normalized stroke work were reduced by only 4.48% and 3.9%, respectively).
Conclusions: Transcatheter intervention that successfully relieves mild COA pressure gradients does not translate to decreased myocardial strain. The effects of the intervention were determined to the greatest degree by ventricular-vascular coupling hemodynamics and provide a novel valuable mechanism to evaluate patients with COA that may influence clinical practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5402700 | PMC |
http://dx.doi.org/10.1016/j.jcin.2016.06.054 | DOI Listing |
Front Cardiovasc Med
October 2024
Division of Vascular and Endovascular Surgery, University of Washington, Seattle, WA, United States.
Ann Pediatr Cardiol
August 2022
Department of Cardiothoracic and Vascular Surgery, Army Institute of Cardiothoracic Sciences, Pune, Maharashtra, India.
Background: Balloon angioplasty (BA) for aortic coarctation in neonates and infants remains controversial due to high recurrence rate and vascular complications.
Aim: This study aimed to determine the safety and outcome of percutaneous treatment of coarctation in neonates and infants and to share the initial experience of strategy of prepartial dilatation with high-pressure noncomplaint balloon before final targeted dilatation using low-pressure compliant balloon.
Materials And Methods: Retrospective analysis of records of all neonates and infants aged <6 months who underwent BA either using only low-pressure balloon (Group A) or those with prepartial dilatation using high-pressure noncomplaint balloon followed by low-pressure compliant balloon (Group B) between July 2017 and February 2020 was performed.
Front Pediatr
March 2020
Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University, Ministry of Education Key Laboratory of Child Development and Disorders, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, National Clinical Research Center for Child Health and Disorders, Chongqing Key Laboratory of Pediatrics, Chongqing, China.
This study aims to summarize the clinical characteristics of coarctation of the aorta (CoA) associated with intracardiac anomalies in infants. Medical records of 93 infants who were diagnosed with CoA and intracardiac anomalies from August 2009 to August 2018 were retrospectively reviewed. All of the 93 infants underwent single-stage repair for CoA associated with intracardiac anomalies.
View Article and Find Full Text PDFJ Biomech
September 2019
Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy. Electronic address:
Severity of aortic coarctation (CoA) is currently assessed by estimating trans-coarctation pressure drops through cardiac catheterization or echocardiography. In principle, more detailed information could be obtained non-invasively based on space- and time-resolved magnetic resonance imaging (4D flow) data. Yet the limitations of this imaging technique require testing the accuracy of 4D flow-derived hemodynamic quantities against other methodologies.
View Article and Find Full Text PDFCardiovasc Revasc Med
December 2018
University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, The Netherlands. Electronic address:
Background: Stenting of coarctation of the aorta (CoA) generally results in good angiographic results and a decrease in transcoarctation pressure gradient. However, effect on blood pressure control is less clear. The goal of the current retrospective analysis was to investigate the effects of CoA stenting on blood pressure control.