Introduction: Objective of our study was to determine the agreement between version 1 (v1) and v2 of the Prostate Imaging Reporting and Data System (PI-RADS) for evaluation of multiparametric prostate MRI (mpMRI) and to compare their diagnostic accuracy, their inter-observer agreement and practicability.
Material And Methods: mpMRI including T2-weighted imaging, diffusion-weighted imaging (DWI) and dynamic contrast-enhanced imaging (DCE) of 54 consecutive patients, who subsequently underwent MRI-guided in-bore biopsy were re-analyzed according to PI-RADS v1 and v2 by two independent readers. Diagnostic accuracy for detection of prostate cancer (PCa) was assessed using ROC-curve analysis. Agreement between PI-RADS versions and observers was calculated and the time needed for scoring was determined.
Results: MRI-guided biopsy revealed PCa in 31 patients. Diagnostic accuracy for detection of PCa was equivalent with both PI-RADS versions for reader 1 with sensitivities and specificities of 84%/91% (AUC = 0.91 95%CI[0.8-1]) for PI-RADS v1 and 100%/74% (AUC = 0.92 95% CI[0.8-1]) for PI-RADS v2. Reader 2 achieved similar diagnostic accuracy with sensitivity and specificity of 74%/91% (AUC = 0.88 95%CI[0.8-1]) for PI-RADS v1 and 81%/91% (AUC = 0.91 95%CI[0.8-1]) for PI-RADS v2. Agreement between scores determined with different PI-RADS versions was good (reader 1: κ = 0.62, reader 2: κ = 0.64). Inter-observer agreement was moderate with PI-RADS v2 (κ = 0.56) and fair with v1 (κ = 0.39). The time required for building the PI-RADS score was significantly lower with PI-RADS v2 compared to v1 (24.7±2.3 s vs. 41.9±2.6 s, p<0.001).
Conclusion: Agreement between PI-RADS versions was high and both versions revealed high diagnostic accuracy for detection of PCa. Due to better inter-observer agreement for malignant lesions and less time demand, the new PI-RADS version could be more practicable for clinical routine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033350 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0162879 | PLOS |
JMIR AI
January 2025
Department of Information Systems and Business Analytics, Iowa State University, Ames, IA, United States.
Background: In the contemporary realm of health care, laboratory tests stand as cornerstone components, driving the advancement of precision medicine. These tests offer intricate insights into a variety of medical conditions, thereby facilitating diagnosis, prognosis, and treatments. However, the accessibility of certain tests is hindered by factors such as high costs, a shortage of specialized personnel, or geographic disparities, posing obstacles to achieving equitable health care.
View Article and Find Full Text PDFJMIR Med Inform
January 2025
Department of Systems Design Engineering, Faculty of Engineering, University of Waterloo, Waterloo, ON, Canada.
Background: While expert optometrists tend to rely on a deep understanding of the disease and intuitive pattern recognition, those with less experience may depend more on extensive data, comparisons, and external guidance. Understanding these variations is important for developing artificial intelligence (AI) systems that can effectively support optometrists with varying degrees of experience and minimize decision inconsistencies.
Objective: The main objective of this study is to identify and analyze the variations in diagnostic decision-making approaches between novice and expert optometrists.
J Vis Exp
January 2025
Department of Biomedical Engineering, Washington University in St. Louis; Department of Obstetrics & Gynecology, Washington University in St. Louis;
For noninvasive light-based physiological monitoring, optimal wavelengths of individual tissue components can be identified using absorption spectroscopy. However, because of the lack of sensitivity of hardware at longer wavelengths, absorption spectroscopy has typically been applied for wavelengths in the visible (VIS) and near-infrared (NIR) range from 400 to 1,000 nm. Hardware advancements in the short-wave infrared (SWIR) range have enabled investigators to explore wavelengths in the ~1,000 nm to 3,000 nm range in which fall characteristic absorption peaks for lipid, protein, and water.
View Article and Find Full Text PDFEur Radiol
January 2025
Department of Urological Surgical, JiangNan University Medical Center, Wuxi, China.
Objective: To conduct a meta-analysis assessing the diagnostic performance of the node reporting and data system (Node-RADS) for detecting lymph node (LN) invasion.
Method: We performed a systematic literature search of online scientific publication databases from inception up to July 31, 2024. We used the quality assessment of diagnostic accuracy studies-2 (QUADAS-2) to assess the study quality, and heterogeneity was determined by the Q-test and measured with I statistics.
Mikrochim Acta
January 2025
Indian Institute of Technology (BHU), Varanasi, 221005, India.
In the modern age, half of the population is facing various chronic illnesses due to glucose maintenance in the body, major causes of fatality and inefficiency. The early identification of glucose plays a crucial role in medical treatment and the food industry, particularly in diabetes diagnosis. In the past few years, non-enzymatic electrochemical glucose sensors have received a lot of interest for their ability to identify glucose levels accurately.