Prosthetic rehabilitation of severely atrophic ridges has always been an ordeal for the clinician due to decreased support, stability and retention. Because of severe resorption the restorative space between maxillary and mandibular residual ridges is increased. Rehabilitation in such cases may result in increased height and weight of the prosthesis further compromising its retention and stability. This in turn overloads the underlying hard and soft tissues exacerbating ridge resorption so, in order to break this vicious cycle, the weight of the prosthesis needs to be reduced which can be achieved by making hollow prosthesis. This article describes a novel technique of fabricating a hollow maxillary complete denture.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5028480PMC
http://dx.doi.org/10.7860/JCDR/2016/20383.8264DOI Listing

Publication Analysis

Top Keywords

hollow maxillary
8
maxillary complete
8
complete denture
8
weight prosthesis
8
innovative simple
4
simple technique
4
technique hollow
4
denture fabrication
4
fabrication prosthetic
4
prosthetic rehabilitation
4

Similar Publications

Modelling Mucus Clearance in Sinuses: Thin-Film Flow Inside a Fluid-Producing Cavity Lined with an Active Surface.

Bull Math Biol

October 2024

Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge, CB3 0WA, UK.

The paranasal sinuses are a group of hollow spaces within the human skull, surrounding the nose. They are lined with an epithelium that contains mucus-producing cells and tiny hairlike active appendages called cilia. The cilia beat constantly to sweep mucus out of the sinus into the nasal cavity, thus maintaining a clean mucus layer within the sinuses.

View Article and Find Full Text PDF

Influence of different designs of bulb support structures on the accuracy and weight of 3D printed maxillary obturators. An in vitro study.

J Prosthet Dent

August 2024

Associate Professor, Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia. Electronic address:

Statement Of Problem: Evidence is lacking on the influence of different designs of bulb support structures on the accuracy of 3-dimensional (3D) printed obturators.

Purpose: The purpose of this in vitro study was to evaluate the influence of various infill designs (hollow, honeycomb, and gyroid) for the bulb of an obturator on the accuracy and weight of digital light projection (DLP) 3D printed maxillary obturators.

Material And Methods: A maxillary obturator was virtually designed and used to obtain 3 digital reference files which were defined based on the design of the infill support structure within the bulb: hollow, honeycomb, and gyroid.

View Article and Find Full Text PDF

Influence of base designs on the manufacturing accuracy of vat-polymerized diagnostic casts using two different technologies.

J Prosthet Dent

August 2024

Senior Lecturer, Planning and Management in Dental Clinics, Stomatology Area, Department of Surgery and Medical-Surgery Specialities, Digital Dentistry Unit of the School of Dentistry, Faculty of Medicine and Dentistry, University of Santiago de Compostela (USC), Santiago de Compostela, Spain.

Statement Of Problem: Diagnostic casts can incorporate different base designs and be manufactured using different vat-polymerization technologies. However, the influence of the interrelation between the base design and the 3D printing technology on the casts' final accuracy remains unclear.

Purpose: The purpose of this in vitro study was to assess the influence of different base designs of 3D printed casts on the accuracy of 2 vat-polymerization technologies.

View Article and Find Full Text PDF

Background: Dental casts made utilising digital workflow are becoming more common because to their speed and cost savings. However, studies on their dimensional accuracy over time with diverse designs are missing.

Objective: The aim of this in vitro study was to assess the dimensional stability of 3D-printed edentulous and fully dentate hollowed maxillary models with 50-micrometer resolution over 1 day, 14 days, and 28 days using surface matching software.

View Article and Find Full Text PDF

A fully digital approach to replacing an obturator prosthesis using a 3D printed closed hollow bulb: Α dental technique.

J Prosthet Dent

March 2024

Professor, Division of Prosthodontics, Department of Restorative Dental Sciences, University of Florida College of Dentistry, Gainesville, Fla; Associate Dean, Clinical Affairs and Quality, University of Florida College of Dentistry, Gainesville, Fla. Electronic address:

The replacement of an obturator prosthesis using conventional methods has multiple issues. Standard tessellation language files generated from the superimposition of an accurate intraoral scanning of the maxillary defect and direct data acquisition of the existing hollow bulb obturator can facilitate the precise design of the prosthesis, requiring only minor adjustments. Rapid prototyping manufacturing techniques seem to ensure precise control of the integrity of the prosthetic component completion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!